EO Abator Operation and Installation Manual
9
Customer
Checklist
6. What is the distance between the indicator panel and the EO
Abator system? (must be less than 40M (130 ft.))
M (ft.)
7. What is the distance between the earth ground and the EO
Abator system? (must be less than 40M (130 ft.))
M (ft.)
8. How many sterilizers and/or aerators are connected to the EO
Abator system? List sterilizer model and quantity.
Model
Quantity
Model
Quantity
Electrical Supply
9. What current is the EO Abator system electrical supply
fused at?
10. What is the supply voltage rating?
11. What is the voltage reading at the EO Abator system?
12. Is an external disconnect switch installed in close proximity to
the EO Abator system?
Yes □
No □
13. Is a 7.5 to 10 KVA boost transformer installed if supply voltage
is 208 VAC?
Yes □
No □
14. What gauge (AWG) ground wire is used for the indicator panel
to control panel connection?
AWG
15. What gauge (AWG) ground wire is used for the earth ground to
the control panel connection?
AWG
16. Are jumper wires installed if only one sterilizer is connected to
the EO Abator system?
Yes □
No □
EO Inlet – Vent line from Sterilizer to Abator
17. Does the EO inlet line connect directly to the EO Abator system
without being terminated into any other exhaust system?
Yes □
No □
18. What type of material is the EO inlet line made of?
19. What is the diameter in mm (in.) of the EO inlet line?
O.D.
20. What is the total length in M (ft.) of the inlet line?
M (ft.)
21. How many sterilizers vent to the EO inlet line?
22. Has the EO inlet line been checked to ensure it is gas tight?
Yes □
No □
Safety Vent Line
23. Does the safety vent line go directly from the EO Abator
system to the outside atmosphere without terminating at any
other exhaust system?
Yes □
No □
24. What type of material is the safety vent line made of?
25. What is the diameter in mm (in.) of the safety vent line?
O.D.
26. What is the length in M (ft.) of the safety vent line?
M (ft.)
27. Does the safety vent line termination have a downward bend?
Yes □
No □
28. Is the safety vent line outlet located within 8 M (25 ft.) of any
possible sources of ignition or any openings to the building
interior?
Yes □
No □