![3Com H3C SECPATH F5000-A5 ADVANCED VPN FIREWALL 12-PORT GIGABIT ETHERNET... Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/3com/h3c-secpath-f5000-a5-advanced-vpn-firewall-12-port-gigabit-ethernet/h3c-secpath-f5000-a5-advanced-vpn-firewall-12-port-gigabit-ethernet_installation-manual_3098102031.webp)
1-25
Table 1-29
Description of the DC power LED
Status
Description
OFF
No power input is present.
Solid green
The power module is working normally.
Solid red
The power module is faulty.
Figure 1-15
DC power module
(1) Captive screw
(2) Power input terminals
(3) Power switch
(4) Power LED
(5) Power module handle
Port Lightning Arrester (Optional)
Before connecting an outdoor Ethernet cable to an Ethernet port, install a port lightning arrester to
protect the device against lightning strokes.
The following port lightning arrester can be installed on the F5000-A5. The specifications for the port
lightning arrester are as follows: Port protective unit–single port, maximum discharge current (8/20
μ
s
waveform): 5 kA, output voltage (10/700
μ
s waveform): core-core < 40 V, core-ground < 600 V.
For the installation of a port lightning arrester, refer to Chapter 4 “Installing the Firewall.”
Power Lightning Arrester (Optional)
Before connecting an outdoor AC power cable to the device, you can install a lightning protection
busbar at the AC power input end to protect the device against lightning strokes. In a heavy lightning
area, you are recommended to install a power lightning arrester.