![3Com CoreBuilder 3500 Скачать руководство пользователя страница 360](http://html1.mh-extra.com/html/3com/corebuilder-3500/corebuilder-3500_command-reference-manual_4589654360.webp)
360
C
HAPTER
14: V
IRTUAL
LAN
S
(VLAN
S
)
bridge vlan modify
(3900/9300/9400/
3500
✓
9000
✓
9400
✓
3900
✓
9300
9000 Layer 2)
Changes a port-based VLAN definition on the indicated system Layer 2
module. See “Important Considerations” for information on when
changes take effect.
To use this command on the CoreBuilder 3500 or CoreBuilder 9000
Layer 3 modules, see the “bridge vlan modify (3500/9000 Layer 3)”
earlier in this chapter.
Valid Minimum Abbreviation
b v modi
Important Considerations
■
You need not reboot the system for the changes to take effect.
However, depending on the number of VLANs that are affected, the
system may take several minutes to return control to you.
■
If you modify the tagging type of a backplane port on a switching
module, make sure that you modify the tagging type of the
corresponding port on the switch fabric module.
■
If tagging is enabled for a port, the software uses the VID as the
802.1Q tag.
■
If you modify the default VLAN, you can only change the member
ports or the tag status. You cannot change the name or the VID.
■
If you modify the tagging for a port shared by another VLAN, verify
that the new tag type does not conflict with the port’s tag type in
another VLAN. (A shared port can use a tag type of
none
for only one
of its VLANs; for all other VLANs to which it belongs, the shared port
must use IEEE 802.1Q tagging.)
Options
Prompt
Description
Possible Values
[Default]
VLAN
interface
index
System-assigned index number that
identifies a VLAN
■
Selectable VLAN
index
■
all
■
? (for a list of
selectable
indexes)
1 (if you
have only
the default
VLAN)
Содержание CoreBuilder 3500
Страница 18: ......
Страница 26: ...26 ABOUT THIS GUIDE...
Страница 27: ...I GETTING STARTED Chapter 1 Administration Overview Chapter 2 Command Summary...
Страница 28: ......
Страница 64: ...64 CHAPTER 2 COMMAND SUMMARY...
Страница 65: ...II SYSTEM LEVEL FUNCTIONS Chapter 3 System Environment Chapter 4 Module Environment...
Страница 66: ......
Страница 147: ...III ESTABLISHING MANAGEMENT ACCESS Chapter 5 Out of Band Management Chapter 6 Simple Network Management Protocol SNMP...
Страница 148: ......
Страница 201: ...IV PHYSICAL PORT PARAMETERS Chapter 7 Ethernet Ports Chapter 8 Fiber Distributed Data Interface FDDI...
Страница 202: ......
Страница 248: ...248 CHAPTER 8 FIBER DISTRIBUTED DATA INTERFACE FDDI...
Страница 250: ......
Страница 320: ...320 CHAPTER 11 TRUNKS...
Страница 368: ...368 CHAPTER 14 VIRTUAL LANS VLANS...
Страница 394: ......
Страница 502: ...502 CHAPTER 17 VIRTUAL ROUTER REDUNDANCY VRRP...
Страница 604: ...604 CHAPTER 19 OPEN SHORTEST PATH FIRST OSPF...
Страница 660: ...660 CHAPTER 20 IPX...
Страница 687: ...VII TRAFFIC POLICY Chapter 22 Quality of Service QoS and RSVP...
Страница 688: ......
Страница 744: ...744 CHAPTER 22 QUALITY OF SERVICE QOS AND RSVP...
Страница 745: ...VIII MONITORING Chapter 23 Event Log Chapter 24 Roving Analysis...
Страница 746: ......
Страница 754: ...754 CHAPTER 23 EVENT LOG...
Страница 764: ...764 CHAPTER 24 ROVING ANALYSIS...
Страница 765: ...IX REFERENCE Appendix A Technical Support...
Страница 766: ......
Страница 772: ...772 APPENDIX A TECHNICAL SUPPORT...
Страница 784: ......