![3Com 7750 Series Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/3com/7750-series/7750-series_command-reference-manual_441219029.webp)
3Com Switch 7750 Series
Command Reference Guide – Login
Chapter 1 Login Commands
1-21
1.1.22 speed
Syntax
speed
speed-value
undo speed
View
User interface view
Parameter
speed-value
: Transmission speed (in bps). This argument can be 300, 600, 1200,
2400, 4800, 9600, 19,200, 38,400, 57,600, and 115,200 and defaults to 9,600.
Description
Use the
speed
command to set the transmission speed of the user interface.
Use the
undo speed
command to revert to the default transmission speed.
Use these two commands in the AUX user interface view only.
Example
# Set the transmission speed of the AUX user interface to 115,200 bps.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] user-interface aux 0
[3Com-ui-aux0] speed 115200
1.1.23 stopbits
Syntax
stopbits
{
1
|
1.5
|
2
}
undo stopbits
View
User interface view
Parameter
1
: Sets the stop bits to 1.
1.5
: Sets the stop bits to 1.5.
2
: Sets the stop bits to 2.