1-11
receive configuration BPDUs and then reports these cases to the administrator. If a port
is shut down, only the administrator can restore it.
Example
# Enable the BPDU protection function.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] stp bpdu-protection
1.1.11 stp bridge-diameter
Syntax
stp bridge-diameter
bridgenum
undo stp
bridge-diameter
View
System view
Parameter
bridgenum
: Network diameter to be set for a switched network. This argument ranges
from 2 to 7.
Description
Use the
stp bridge-diameter
command to set the network diameter of a switched
network. The network diameter of a switched network is represented by the maximum
possible number of switches between any two terminals in a switched network.
Use the
undo stp bridge-diameter
command to revert to the default network diameter.
By default, the maximum number of switches between any two terminal devices in the
switched network is 7.
After you configure the network diameter of a switched network, MSTP adjusts its Hello
time, Forward delay, and Max age settings accordingly. With the network diameter set
to 7 (the default), the three time-relate settings, Hello time, Forward delay, and Max age,
are set to their defaults as well.
The
stp bridge-diameter
command only applies to CIST; it is invalid for MSTIs.
Related command:
stp timer forward-delay
,
stp timer hello
, and
stp timer max-age
.
Example
# Set the network diameter to 5.
<3Com> system-view
System View: return to User View with Ctrl+Z.
Содержание 7750 Series
Страница 520: ...3Com Switch 7750 Series Command Reference Guide Multicast Table of Contents iii 5 1 22 static rp 5 20 ...
Страница 808: ...3Com Switch 7750 Series Command Reference Guide ACL Chapter 1 ACL Commands 1 27 3Com time range test from 0 0 2000 1 1 ...
Страница 1177: ...3Com Switch 7750 Series Command Reference Guide Command Index Appendix A Command Indexx A 45 ...