3Com Switch 7750 Series
Command Reference Guide – PoE
Chapter 2 PoE PSU Supervision Configuration Commands
2-9
2.2.4 poe-power output-thresh upper
Syntax
poe-power output-thresh upper
string
View
System view
Parameter
string
: Overvoltage alarm threshold (in volts V) in the format of X.X, in the range of 55.0
to 57.0.
Description
Use the
poe-power output-thresh upper
command to set the overvoltage alarm
threshold of DC output for the external PoE PSUs.
For either 220 VAC or 110 VAC input, the recommended threshold is 55.0 V.
Example
# Set the overvoltage alarm threshold of DC output for the external PoE PSUs to 55.0
V.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] poe-power output-thresh upper 55.0
Set upper output-threshold power successfully!