3Com Switch 7750 Series
Command Reference Guide — Basic Port Commands
Chapter 1 Port Basic Configuration Commands
1-25
1.1.26 port monitor last
Syntax
port monitor last
[
value
]
undo port monitor last
View
Ethernet port view
Parameter
value
: Delay of reporting down state to the system, in the range of 0 to 60. When this
argument is set to 0, the port will report its state as soon as it is brought down. The
bigger this argument is, the longer delay it takes for a port to report its down state to the
system.
Description
Use the
port monitor last
command to set the delay of reporting down state to the
system for the current port.
Use the
undo port monitor last
command to restore the delay of reporting down state
to the system for the current port to the default value, which is related to the
configuration performed in system view:
z
If you have configured the global delay in stem view (refer to 1.1.27 port monitor
last slot for details), the default delay will be the global delay.
z
If no global delay is configured, the default delay is 1.
Note:
The delay of reporting down state to the system can be configured in either system view
or Ethernet port view. If the delay is configured in both system view and Ethernet port
view simultaneously, the configuration performed in Ethernet port view is given priority.
After the setting, you can use the
display interface
command to display the
information about the field “Port monitor last value”.
Example
# Set the delay of reporting down state to the system to 5 for Ethernet1/0/1.
<3Com> system-view
System View: return to User View with Ctrl+Z.
[3Com] interface Ethernet1/0/1
[3Com-Ethernet1/0/1] port monitor last 5