80
C
HAPTER
4: XRN C
ONFIGURATION
Table 60
Configuring FTM
The Switch 5500 Series: the SI units supports basic XRN, that is, Distributed Device
Management (DDM) and Distributed Link Aggregation (DLA); the EI units support
enhanced XRN, that is DDM, Distributed Resilient Routing (DRR).
Specifying the Stacking
VLAN of the Switch
You can use the command in the following table to specify the
stacking
VLAN of the
Switch.
Perform the following configuration in System View.
Table 61
Specifying the
Stacking
VLAN of the Switch
By default, the stacking VLAN is VLAN 4093.
You should specify the stacking VLAN before the Fabric is established.
Setting Unit IDs for
Switches
You can use the command in the following table to set unit IDs for Switches. Make
sure to set different unit IDs for different Switches in a Fabric. On the Switches that
support auto numbering, FTM will automatically number the Switches to constitute a
Fabric, so that each Switch has a unique unit ID in the Fabric.
Perform the following configuration in System View.
Table 62
Setting unit IDs for Switches
n
If the modified unit ID does not exist in the Fabric, the Switch sets its priority to 5
and saves it in the unit Flash memory.
Device
Configuration
Default Settings Comment
Switch
Specify the stacking
VLAN of the Switch
The stacking
VLAN is VLAN
4093
You should specify the stacking
VLAN before the Fabric is
established.
Set unit IDs for the
Switches
The unit ID of a
Switch is set to 1
Make sure that you have set
different unit IDs to different
Switches, so that the Fabric can
operate normally after all the
Switches are interconnected.
Specify the Fabric
port of the Switch
-
For 28-port Switch, the 27
th
28
th
port can be the Fabric port, for
52-port Switch, the 51
st
, 52
nd
port
can be the Fabric port.
Set unit names for
the Switches
-
-
Set a name for the
Fabric where the
Switches belong
The Fabric name
of the Switches is
5500
Interconnected the Switches with
the same Fabric name to form a
Fabric.
Set the
authentication
mode for the Fabric
No authentication
mode is set on the
Switches
Set the same authentication mode
on all the devices within the Fabric.
Operation
Command
Specifying the stacking VLAN of the Switch
ftm stacking-vlan
vlan-id
Setting the stacking VLAN of the Switch to Default Value
undo ftm stacking-vlan
Operation
Command
Set unit IDs for Switches
change unit-id <1-8> to {<1-8> |
auto-numbering }
Содержание 5500 SI - Switch - Stackable
Страница 24: ...24 ABOUT THIS GUIDE...
Страница 30: ...30 CHAPTER 1 GETTING STARTED Figure 3 Setting up a New Connection Figure 4 Configuring the Port for Connection...
Страница 50: ...50 CHAPTER 1 GETTING STARTED...
Страница 54: ...54 CHAPTER 2 ADDRESS MANAGEMENT CONFIGURATION...
Страница 78: ...78 CHAPTER 3 PORT OPERATION...
Страница 88: ...88 CHAPTER 4 XRN CONFIGURATION...
Страница 122: ...122 CHAPTER 8 VLAN VPN CONFIGURATION...
Страница 216: ...216 CHAPTER 15 SSH TERMINAL SERVICES...
Страница 268: ...268 CHAPTER 16 IP ROUTING PROTOCOL OPERATION...
Страница 308: ...308 CHAPTER 17 NETWORK PROTOCOL OPERATION...
Страница 349: ...349...
Страница 350: ...350 CHAPTER 18 MULTICAST PROTOCOL...
Страница 522: ...522 CHAPTER 22 FILE SYSTEM MANAGEMENT...
Страница 584: ...584 CHAPTER 30 PASSWORD CONTROL CONFIGURATION OPERATIONS...
Страница 600: ...600 CHAPTER 31 MSDP CONFIGURATION...
Страница 614: ...614 CHAPTER 32 CLUSTERING...
Страница 670: ...670 CHAPTER C AUTHENTICATING THE SWITCH 5500 WITH CISCO SECURE ACS...