Local card loopback
A loopback is turned on.
Loopbacks are for troubleshooting only and should not be present
under normal operating conditions.
Network card loopback A loopback is turned on.
Loopbacks are for troubleshooting only and should not be present
under normal operating conditions.
Card not installed
Required card physically is not present.
Card initialized
Card initialized
Cellbus parity
Parity error on cells received from cell bus.
Receive FIFO overflow
Cells received from the cell bus faster than the CBR can process
them.
Transmit FIFO overflow
Cell bus is congested and cells are backed up on the CBR.
Traffic at the output side of the CBR port is being transmitted slower
than it is being received from the cell bus and so the output buffer is
overflowing. In general, the problem is that the CBR connection is
not synchronized end-to-end. The clock rate of the output port does
not match the clock rate of the device from which the traffic
originated.
LP cellbus congested
Low priority cell bus congested.
MP cellbus congested
Medium priority cell bus congested.
HP cellbus congested
The cell port has been configured to pass more CBR traffic than it
can physically handle. The aggregate bandwidth of the CBR
connections exceeds the total bandwidth of the port. It indicates
that you either mistakenly oversubscribed the cell port with CBR
connections, or more connections than expected are simultaneously
active. When this condition exists on the HP Cellbus, lower priority
cell busses will not be able to pass traffic out.
Shelf Mismatch
Mismatch shelf is found (Shelf ID is incorrect)
Login Failure
Failed log -in
SAR SRAM failure
SAR SRAM failure (applicable to QSIM, Ethernet, HSIM, FAM, CBR)
E1 channel 16 AIS Rcv
All 1’s in the E1 time slot 16 for 2 consecutive frames.
E1 loss of CAS
multiframe
E1 signaling multiframe alignment has been lost.
Far end E1 loss of CAS
The far end device has lost Channel Associated Signalling.
Port Yellow
OOF alarm is detected. A received remote alarm indication means
that the far-end equipment has a problem with the signal it is
receiving from the PathBuilder device.
A received remote alarm indication means that the far-end
equipment has a problem with the signal it is receiving from the
PathBuilder device.
VC RDI Received
VC RDI (Remote Defect Indication) OAM received in the connection.
The far end equipment has a problem with the signal it is receiving,
indicating that the problem lies between the network provider and
the far-end terminal equipment for this connection.
BITS reference clock
failure
Enabled when BITS clock is selected as the timing source, but has
failed.
CBR reference clock
failure
Interface clock has been designated as the system clock, and the
interface clock has failed.
(continued)
Table 36
PathBuilder S600 Alarm Messages (continued)
Alarm
Definition
Содержание 3C63100-AC-C - PathBuilder S600...
Страница 8: ...INDEX 3COM CORPORATION LIMITED WARRANTY ...
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...18 ABOUT THIS GUIDE ...
Страница 28: ...28 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 74: ...74 CHAPTER 3 GETTING STARTED ...
Страница 230: ...230 INDEX ...