Configuring the PathBuilder S600 Shelf and the Application Modules
115
The options on the Configuration Management menu correspond to the major
steps involved in configuring the PathBuilder S600:
n
Configuring application modules
n
Setting up virtual circuits and assigning them to the appropriate card’s ports
n
Configuring application-specific options
Specialized functions such as bridging of the LAN traffic and IP over ATM can
be applied to virtual circuits as needed and/or supported.
Configuring the
PathBuilder S600 Shelf
and the Application
Modules
The starting point for configuring the PathBuilder S600 shelf and the application
modules is the List Card menu, shown in Figure 80. To display the List Card menu:
From the Configuration Management menu, select
[1] Manage Card.
Figure 80
List Card Menu
The List Card menu lists the PathBuilder S600 shelf and all the modules installed in
the shelf. The numbers corresponds to the slot numbers. For each slot number, the
List Card menu displays:
Config Card Type
—The type of module configured for the slot.
Actual Card Type
—The type of module actually installed in the slot.
To access the configuration menu(s) for a particular module, simply enter the
corresponding slot number.
The configured card type must match the actual card type before you can access
the configuration menus for that card. If there is a mismatch between the
configured card type and the actual card type, an error message appears when
you enter the slot number from the List Card menu.
Содержание 3C63100-AC-C - PathBuilder S600...
Страница 8: ...INDEX 3COM CORPORATION LIMITED WARRANTY ...
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...18 ABOUT THIS GUIDE ...
Страница 28: ...28 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 74: ...74 CHAPTER 3 GETTING STARTED ...
Страница 230: ...230 INDEX ...