Camera current draw table.
No Lamps
IR80/
SIR110
IR110WL/
SIR140WL
IR130/
SIR160
IR175SW/
SIR250WL
IR200/
SIR275
Power Up
1.2A
1.2A
1.2A
1.2A
1.2A
1.2A
Idle
(No Lamps)
0.83A
0.83A
0.83A
0.83A
0.83A
0.83A
PTZ/Wiper
(No Lamps)
1.45A
1.45A
1.45A
1.45A
1.45A
1.45A
Idle
(IR Lamps)
N/A
2.3A
2.3A
3.1A
3.1A
3.1A
PTZ/Wiper
(IR Lamps)
N/A
3.1A
3.1A
3.8A
3.8A
3.8A
Idle
(White Lamps)
N/A
N/A
2A
N/A
2A
N/A
PTZ/Wiper
(White Lamps)
N/A
N/A
2.7A
N/A
2.7A
N/A
Voltage at PSU
30Vdc
30Vdc
30Vdc
30Vdc
30Vdc
30Vdc
Voltage at Camera
(PTZ/IR Fast tour)
28.5Vdc
(No Lamps)
27Vdc
27Vdc
27Vdc
27Vdc
27Vdc
Current/Voltage test at
cable length (1.5mm²)
40m
40m
40m
40m
40m
40m
Ethernet connections between Predator PSU and Predator that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
• Open the hinge taking care that the gasket is not damaged and support the weight of the Predator.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support the
weight of the Predator, there is no need to continue to support the Predator. The connection circuit
board can now be seen.