Predator-Dualview Installation Manual V2.1.21.1
Page 8
© 360 Vision Technology Ltd.
5 Connections to Predators with HMA
When the HMA (Hinged Mount Adaptor) is fitted to the Predator, the ‘Predator Composite Cable’ is not used.
Connections between the power supply and Predator use conventional cables as detailed below.
30Vdc Power connections between Predator PSU and Predator that is fitted with HMA
Cable Size
No IR
SIR110
SIR140WL
SIR160
0.75mm²
85m
32m
32m
30m
1.00mm²
113m
43m
43m
40m
1.25mm²
141m
54m
54m
50m
1.50mm²
170m
65m
65m
60m
2.50mm²
283m
108m
108m
100m
3.00mm²
340m
130m
130m
120m
4.00mm²
450m
173m
173m
160m
Ethernet connections between Predator PSU and Predator that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.