Manual WS.502 v1.5
2-Wire Energy Monitor
3
At the bottom where the network cable is plugged in,
a green LED should be lit, and regularly an orange LED.
Then the network connection is fine. If EC.441 or
RG.016 modules are connected, the powerled of
these modules must light up.
4. NETWORK SETTINGS
By default, the WS.502 is on
'FIXIP',
which means
that at the first boot the IP address is standard at
192.168.0.123:8080. To change or verify this address,
the 'ServerScanner' program is available. You can
download this program on the website of 2-WIRE.
https://www.2-wire.net/product/ip-serverscanner/
Start this program and press the green button until
data appears.
(Sometimes multiple attempts are required)
You can keep the found IP address or you can change
the network settings from the server scanner with the
'Set IP' button
to 'Suggested for Lowi/server' so that Memo will be
in your network range or
you can set the Memo server to DHCP and after
restarting the Memo it will be assigned an IP address
from your router which you will find with the server
scanner.
Note HARD RESET to fixed IP address
Should DHCP fail, and you want to return to the
default address (192.168.0.123:8080), you can follow
the following procedure:
Procedure: Turn off voltage of the WS502, wait 5
seconds, hold down key S2, turn on voltage, and keep
pressing until the LED starts flashing. Keep pressing for
another 3 seconds until the LED stops blinking, and
then release the key. After about 5seconds all LEDs are
off and the WS502 is at a fixed address. You must now
'surf' to the default IP address: 192.168.0.123:8080
(100% tested and recommended browser = Google
chrome)
Note. This standard address is not always suitable for
the network where your PC or laptop is connected.
When you're in a different range, you'll need to adjust
the web server's network settings via the IPserver
scanner to suggested for lowi/server! Further
explanation can be found at addendum 'problem
solutions'
As soon as an IP address is assigned, you can surf to
the IP address by typing it into the address bar of a
web browser, including the port number!
(recommended: google chrome)
The gate No. is standard on '8080'. As an example,
you type in: 192,168. 1.122:8080
Note the
colon
between address and port number!
The next login screen should
now appear. If this is not the
case, check the connections of
the web server again.
Login with login and password:
'
adminIP
' and password '
2015
'
With this login you can change all IP settings, but not
change a password (this should be done with login
'
admin2-WIRE'
and
password
'2015
')