Manual WS.502 v1.5
2-Wire Energy Monitor
22
RESULT:
relay according to the input status and the selector:
•
NO RELAY: no relay control
•
RELAY ON: relay is turned on when input is on,
afterwards relay stays on even if the entrance
goes out
•
RELAY OFF: relay is turned off when input is
out, afterwards relay remains off even if the
entrance is on
•
RELAY FOLLOW: relay follows the status of the
entrance
•
RELAY INVERS: relay follows the inverse status
of the entrance.
The channel No must of course be a channel with
which the relay module is connected.
In the case of 'MAIL', a mail address can be entered
where a message must be sent.
The content will be a short notice with the status of
that output (e.g. Fuel credit < 100l)
NOTE: The mail server
does not have 'SMTP
authentication'.
For some providers, this mail ends
up in the 'SPAM'.
Example of an email received:
WIRING:
the 'wiring' of modules can only be done if starting on
an 'output', and connecting them to an input.
To remove a connection: Stand with mouse cursor on
the INPUT, click left, go with cursor to blank place
(gray grid) and click back left.
An output can be connected to multiple inputs, but an
input can only have one connection atany time.
11.LAYOUT
Go to the
'CHANNELS'
menu.
We now see channel
names in the same arrangement as we created them
in our modules, but maybe this isn't the order you like
them to see in the dashboard. It is also interesting to
create 'groups'.