Parameter
(function)
Parameter
Name
Range
Default
Note
951
Minimum
ringing tone
time
1–
200
50 = 0,5
s 2)
The longest ringing period pause
must be in the interval between
parameters 952 and 953.
Warning! As these parameters
also detect incoming calls, an
incorrect setting may result in the
intercom not answering the call!
952
Minimum
long pause
time
5–
100
10 = 1 s
953
Maximum
long pause
time
10–
100
60 = 6 s
954
Count of
ringing
periods
1–99
10
If the preset count of periods is
exceeded, the call is terminated.
If the preset count of periods is exceeded and automatic dialling is enabled, another
attempt follows. In the event of Automatic Dialling
, the ringing
without Confirmation
tone is recognised and ends before the preset count of periods is exhausted; the
call is regarded as successful.
961
Maximum
timeout for
pressing the
next digit
1–9
5 s
During password entering, etc.
963
Possibility to
hang up by
pressing the
same button
0 = no
1 = yes
1