If you do not press any button within a predefined timeout, the intercom sends a
hang-up signal and hangs up. The timeout is 5 seconds; every
character is
followed by 30 seconds for you to think over your setting. The 5-second limit
starts when the intercom has read all that relates to the current user position in
the programming menu. The timeout can be prolonged – see the chart.
Tip
To check programmed values: enter parameter number and
, listen
the parameter value and press
for return to the main menu.
Deleting All Passwords, All Memories, Complete Initialisation
The following three functions facilitate your programming by clearing all previous
settings:
997 – deletes the entire password list for switch including password 00.
998 – deletes memories of all buttons (01–02) plus Arrival/Departure and Day
/Night passwords.
999 – clears the whole memory and resets the default values (see the chart).
Protection against Unintentional Deletion
The above functions need no special "value" but must be protected against
unintentional initiation. Therefore, enter the service password as the value. Warning:
Full initialisation takes a few seconds, the intercom sends a continuous tone while
memory clearing. Functions 997 and 998 take a little less time and are signalled by a
continuous tone too.
The button memories can be deleted individually too – just enter a "blank" while
programming. For example:
– clears memory 1 of button 01.
CIE-Group Ltd, www.cie-group.com 29 / 63
Содержание 9153201-E
Страница 1: ...2N Helios Uni Door Access Intercom Installation Manual Version 1 1 CIE Group Ltd www cie group com ...
Страница 20: ...Dimension for wall surface mounting CIE Group Ltd www cie group com 20 63 ...
Страница 25: ...CIE Group Ltd www cie group com 25 63 ...
Страница 54: ...Templates Nametags CIE Group Ltd www cie group com 54 63 ...
Страница 63: ...CIE Group Ltd www cie group com 63 63 ...