Prestige 724 G.SHDSL CSU/DSU
Troubleshooting
6-1
Chapter 6
Troubleshooting
This chapter covers potential problems and the corresponding remedies.
Table 6-1 Problems Starting the Prestige
PROBLEM
CORRECTIVE ACTION
No LEDs are on when I
turn on the Prestige.
Check the connection between the adapter and the Prestige.
If this error persists, you may have a hardware problem. If this is the case,
you should contact your vendor.
1. Check to see if the Prestige is connected to your computer’s serial port.
VT100 terminal emulation.
9600 bps is the Prestige’s factory default speed.
Try other speeds in case it has been changed.
Cannot access the Prestige
via the console port.
2. Check to see if the
communications
program is configured
correctly. It should be
configured as follows:
No parity, 8 data bits, 1 stop bit, no flow control.
Table 6-2 Problems Connecting with the WAN or Channel/ISP
PROBLEM
CORRECTIVE ACTION
Cannot initialize the
PVC connection.
Verify the xDSL port/wall jack cable connection. The xDSL LED should be on. If
not, verify in menu 24.1 that the
Line Status
is Down. Wait ten minutes until the
PVC synchronizes and the field reads Up. If the field does not eventually read Up,
verify in menu 2 that
Service Type
(Client or Server) and
Transfer Rate
are the
same as the peer. If problems persist, check with the telephone company, ISP
and/or the peer device (in a LAN-to-LAN application).
Cannot connect to a
channel or ISP.
Check menu 11.1 to verify the correct
Encapsulation
for the channel.
Check remote management configuration in menu 11.1.