NetAtlas Enterprise Ethernet Switch Manager User’s Guide
51
Chapter 5 View
Table 16
Status: Hardware Status
LABEL
DESCRIPTION
Fan RPM (RPM) A properly functioning fan is an essential component (along with a sufficiently
ventilated, cool operating environment) in order for the device to stay within the
temperature threshold. Each fan has a sensor that is capable of detecting and
reporting if the fan speed falls below the threshold shown.
Index
This field displays the fan number.
Current
This field displays this fan’s current speed in Revolutions Per Minute (RPM).
Max
This field displays this fan’s maximum speed recorded in Revolutions Per Minute
(RPM).
Min
This field displays this fan’s minimum speed recorded in Revolutions Per Minute
(RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Status
NORMAL
indicates that this fan is functioning above the minimum speed.
ERROR
indicates that this fan is functioning below the minimum speed.
Voltage (V)
The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range.
Index
This field displays the first voltage sensor number.
Current
This is the current voltage reading in volts.
Max
This field displays the maximum voltage recorded at this sensor in volts.
Min
This field displays the minimum voltage recorded at this sensor in volts.
Threshold
This field displays the minimum voltage percentage at which the switch should work.
Status
NORMAL
indicates that the voltage is within an acceptable operating range at this
point; otherwise
ERROR
is displayed.
ABSENT
indicates that there is no power
reading at a sensor(s).
Temperature
The switch has temperature sensors that are capable of detecting and reporting if the
temperature rises above the threshold. You may choose the temperature unit (in
degrees Celsius or Fahrenheit).
Celsius
Select this option to display the temperature in degrees Centigrade.
Fahrenheit
Select this option to display the temperature in degrees Fahrenheit.
Index
This field displays the temperature sensor number.
Current
Value
This shows the current temperature at this sensor.
Max
This field displays the maximum temperature recorded at this sensor.
Min
This field displays the minimum temperature recorded at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Status
This field displays
NORMAL
for temperatures below the threshold and
ERROR
for
those above.
Polling
The text box displays how often (in seconds) this screen refreshes. You may change
the refresh interval by typing a new number in the text box and then clicking the
Apply
button.
Close
Click
Close
to close the screen.
Summary of Contents for NETATLAS ENTERPRISE -
Page 1: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Version 1 02 1 2006 ...
Page 21: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 21 List of Tables ...
Page 27: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 27 Chapter 1 Introduction ...
Page 35: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 35 Chapter 2 Switch Manager ...
Page 45: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 45 Chapter 3 EMS Main Window ...
Page 67: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 67 Chapter 5 View ...
Page 91: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 91 Chapter 9 Fault ...
Page 99: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 99 Chapter 10 Maintenance ...
Page 103: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 103 Chapter 11 Tools ...
Page 109: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 109 Chapter 12 Device Menu Overview ...
Page 119: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 119 Chapter 13 System Configuration ...
Page 133: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 133 Chapter 14 Switch Configuration ...
Page 191: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 191 Appendix A SNMPc Network Manager ...
Page 193: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 193 Appendix B ...