NetAtlas Enterprise Ethernet Switch Manager User’s Guide
153
Chapter 16 Ethernet Port Configuration
\
The following table describes the labels in this screen.
Table 79
Ethernet Port Configuration: Bandwidth Ctrl.
LABEL
DESCRIPTION
Active
Select this check box to enable bandwidth control on the selected port(s).
You may temporarily deactivate a rule without deleting it by clearing this check box.
Ingress Rate
Type the maximum bandwidth allowed in kilobits per second (Kbps) for traffic coming
into this port.
Commited
Rate
Specify the guaranteed bandwidth allowed in kilobits per second (Kbps) for the incoming
traffic flow on a port. The commit rate should be less than the peak rate. The sum of
commit rates cannot be greater than or equal to the uplink bandwidth.
Peak Rate
Specify the maximum bandwidth allowed in kilobits per second (Kbps) for the incoming
traffic flow on a port.
Egress Rate
Type the maximum bandwidth allowed in kilobits per second (Kbps) for traffic going out
of this port.
Scheme
Select
Drop
(default) from the drop-down list box to discard all incoming packets that
are over the maximum allowable bandwidth on a port.
A concentration of traffic on a port decreases port bandwidth and overflows buffer
memory causing packet discards and frame losses.
Flow Control
is used to regulate
transmission of signals to match the bandwidth of the receiving port.
The switch uses IEEE 802.3x flow control in full duplex mode and backpressure flow
control in half duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the
sending port, causing it to temporarily stop sending signals when the receiving port
memory buffers fill. Back Pressure flow control is typically used in half duplex mode to
send a "collision" signal to the sending port (mimicking a state of packet collision)
causing the sending port to temporarily stop sending signals and resend later. Select
this option to enable flow control.
Apply
Click
Apply
to save the changes.
Summary of Contents for NETATLAS ENTERPRISE -
Page 1: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide Version 1 02 1 2006 ...
Page 21: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 21 List of Tables ...
Page 27: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 27 Chapter 1 Introduction ...
Page 35: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 35 Chapter 2 Switch Manager ...
Page 45: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 45 Chapter 3 EMS Main Window ...
Page 67: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 67 Chapter 5 View ...
Page 91: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 91 Chapter 9 Fault ...
Page 99: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 99 Chapter 10 Maintenance ...
Page 103: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 103 Chapter 11 Tools ...
Page 109: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 109 Chapter 12 Device Menu Overview ...
Page 119: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 119 Chapter 13 System Configuration ...
Page 133: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 133 Chapter 14 Switch Configuration ...
Page 191: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 191 Appendix A SNMPc Network Manager ...
Page 193: ...NetAtlas Enterprise Ethernet Switch Manager User s Guide 193 Appendix B ...