3-33
3
Backspace
Character
(S5=0-32,127)
Register S5 defines the ASCII character used as the
backspace character. The backspace character causes
the cursor to move backwards in a line, deleting the
characters. If the backspace character is set to a value
between ASCII 33 and 127 or a value greater than 127,
the modem does not recognize it.
Default = 8 (ASCII
backspace)
.
Dial Tone Delay
(S6=2-255)
Register S6 determines how long the modem will wait
after going off-hook before dialing the telephone
number. The S6 register is in effect when the
X
command is set to 0, 1 or 3. When the
X
command is
equal to 2 or 4, this register is ignored. Also, since the
W modifier overrides S6, the modem will wait the length
of the failed call timer (S7) for dial tone when the W
modifier is part of the dial command string.
Default = 2
(seconds).
Wait Time for
Carrier/Silence
(S7=1-255)
Register S7 controls the wait time for carrier or wait
time for silence. If the at sign (@) is used in the dialing
command string, register S7 also controls the wait time
for silence; otherwise, after dialing a call, the modem
must receive a valid carrier signal within the specified
wait time. If carrier is not received within that specified
wait time, the modem sends a NO CARRIER message to
the DTE. Register S7 is also active when the modem
answers a call. This register should be set to at least 90
for international calls.
Default = 60 (seconds)
.
Summary of Contents for Z34-PL
Page 1: ...Zypcom Data Fax Modems User s Guide Z34 SL Z34 PL Part number 18008 513A August 1997...
Page 3: ...Zypcom Data Fax Modems User s Guide Z34 SL Z34 PL Part number 18008 513A August 1997...
Page 16: ...xiv Z...
Page 92: ...4 16 4...
Page 96: ...Appendix A 4 A...
Page 100: ...B Appendix B 4...
Page 110: ...D Appendix D 4...
Page 114: ...Appendix E 4 E...