FV746 Rev. A 11/10/20
Page 3
STEP A
Use battery compartment wrench
to remove battery compartment tray.
STEP B
Pull cover off by rotating battery
side forward and out.
STEP C
Sensor Adjustor Tool comes in a
built-in storage pocket. Replace after use.
Flush Valve Activation
Visual Indicator Guide
Adjusting Your E-Z Flush
1
2
3
4
Using supplied battery compartment wrench,remove battery
compartment from the E-Z Flush™ unit.
Load batteries into compartment tray (note position of batteries in
tray), and reinstall battery tray into the E-Z Flush unit.
Secure tray with battery compartment wrench. The last three turns
of the wrench will activate the E-Z Flush unit. The E-Z Flush System
is now operational.
Your E-Z Flush unit comes preset from the factory. If special
circumstances require adjustment of the activation distance, see
Appendix A – Adjusting Your E-Z Flush.
The E-Z Flush unit has a 10-minute start-up sequence in which
the Object Lock Sensor will flash the User-In-View
yellow L.E.D.
continuously as long as a user is in view. After the start-up
sequence is completed and when the Object Lock Sensor has a
user in view, the User-In-View
yellow L.E.D.
will flash only 3 times
after a 5-second delay. This delay prevents needless flushes when
someone walks by. Sensor units should not be located across from
each other or in close proximity to highly reflective surfaces.
1. USER-IN-VIEW L.E.D.
Yellow light flashes 3 times – after 5-second delay – when a
user is in view. The yellow light flashes constantly when a user
is in view during the 10-minute start-up sequence.
2.
OBJECT LOCK SENSOR
3. BATTERY L.E.D.
Red light flashes indicating it is time to replace batteries with 4
new “C” batteries.
4.
COURTESY MANUAL FLUSH BUTTON
Allows manual activation of flush when needed.