Part Identification

 1. Seal

  2.  Collar Gasket

  3.  Sensor Module

  4.  Manual Overide Push Button

  5.  Replacement Sensor Lens

  6.  Chrome Plastic Cover

  7.  Chrome Metal Cover

  8.  Battery Drawer

  9.  O-Ring

 10. Allen Wrench

 11. Handle Nut Wrench

 12. Valve Body Cover 

 13. Plastic Cover

 14. Trip Mechanism 

15. Diaphragm Repair Kit 

 16. Valve Body

 17. Vacuum Breaker Duckbill

 18. Vacuum Breaker Tube 

 19. Vacuum Breaker Tube Nut 

 20. Spud Nut

 21. Spud Friction Washer 

 22.  Spud  Sleeve

 23. Spud Escutcheon

 24. Tailpiece 

 25.  Snap  Ring 

 26. Tailpiece O-Ring 

 27. Locking Nut 

 28. Setscrew for Cast Wall Flange

 29. Cast Wall Escutcheon

 30. Supply Cover Tube

 31. Sweat Solder Adapter

 32. Stop Body

 33. Piston Seal 

 34. Piston 

 35. Stop Spring

 36. Guide O-Ring

 37. Piston Guide

 38. Guide Holder

 39. Adjusting Screw 

 40. Stop Cap 

 41. Snap Cap Screw Cover

 42. Vandal - Resistant Control Stop 

Cover

 43. Setscrew for Control Stop Cover

Covers and Repair Kits

Product No.

Outside Cover - CP - Item 10

P6000-LL-CP

Inside Cover - Item 11

P6000-L

Low Consumption Closet Kit - 1.28 gal. flush

P6000-ECA-HET

Low Consumption Closet Kit - 1.6 gal. flush

P6000-ECA-WS1

Water Saving Closet Kit - 3.5 gal. flush

P6000-ECA-WS

Full Flow Closet Kit - 4.5 gal. flush

P6000-ECA-FF

Ultra Low Flush Urinal Kit - 0.125 gal. flush

P6000-EUA-ULF

Extra Water Saver Urinal Kit - 0.5 gal. flush

P6000-EUA-EWS

Low Consumption Urinal Kit - 1.0 gal. flush

P6000-EUA-WS1

Water Saving Urinal Kit - 1.5 gal flush

P6000-EUA-WS

Full Flush Urinal Kit - 3.0 gal. flush

P6000-EUA-FF

Repair Parts - Inside Parts

Product No.

Urinal Relief Valve - Item 12

P6000-EU13

Closet Relief Valve - Item 12

P6000-EC13

Flush Connections and Spud Coupling 

Kits

Product No.

Flush Tube Assembly for Flush Valves 

Includes Items 15-19, Specify Diameter and 

Length

P6000-A

Vacuum Breaker Repair Kit, Item 17

P6000-B

Spud Coupling Assembly Includes Items 20-

23 Specify Size.

P6000-H

Control Stop Repair Kit and Parts

Product No.

Control Stop Repair Kit for 1” and 3/4”, 

Includes Items 33-39

P6000-D-SD

Seal Seat for 1” and 3/4”, Includes Item 33

P6000-D42

VP Control Stop Repair Kit for 1” and 3/4”,  

Includes Items 33-39

P6000-D-VP

Sweat Solder Connection with Cast Wall 

Flange, Includes Items 29-31

P6000-YBYC

Adjustable Tailpieces

Product No.

Adjustable Tailpiece for Standard Flush Valve 

Includes Items 24-26

P6000-J1

Tailpiece Coupling Assembly Includes Items 

25-27

P6000-K

Tailpiece Locking Ring Includes Item 25

P6000-C30

Tailpiece O-Ring Includes Items 26

P6000-C31

Coupling Nut Includes Item 27

P6000-C32

Handle Assembly and Repair Kits

Product No.

Chrome Plastic Cover, Item 6

PERK6000-L-CPCR

Chrome Metal Cover, Item 7

PERK6000-L-CPMCR

Replacement Sensor Lens Item 5

PERK6000-SCR

Battery Drawer, Item 8

PERK6000-BD

Repair Kit Includes Items 1, 2, 4, and 9

PERK6000-RK

Repair Kit Includes Items 1, 2, Retainer and 

Cup Seal

PERK6000-MRK

Sensor Module

PERK6000-SR

 Connected ZER6000 Series Parts Breakdown

Summary of Contents for AquaSense ZER-W2 Series

Page 1: ... and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall b...

Page 2: ...mmunications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase t...

Page 3: ...r than this measurement Deburr by chamfering O D and I D of end of water supply pipe NOTE Before installation turn off water supplies to existing fixture and remove flushometer if replacing an existing device Finished Wall Water Supply Pipe Center Line of Fixture Spud 11 4 Sweat Solder Adapter Set Screw Chrome Cover Tube Wall Escutcheon Distance to Measure 2 Slide threaded sweat solder adapter ont...

Page 4: ... to control stop inspect and verify that the O ring seal is located within the O ring groove at the tailpiece Ensure that the locking nut and locking snap ring are also present on the tailpiece Flush Valve Installation Instructions Lubricate O ring with water if necessary and insert flush valve tailpiece into the control stop valve Tighten locking nut using a smooth jawed wrench Vacuum Breaker Tub...

Page 5: ...e adjustment of the activation distance see Appendix A Adjusting Your E Z Flush The E Z Flush unit has a 10 minute start up sequence in which the Object Lock Sensor will flash the User In View yellow L E D continuously as long as a user is in view After the start up sequence is completed and when the Object Lock Sensor has a user in view the User In View yellow L E D will flash only 3 times after ...

Page 6: ... valve shown on the right 3 Replace the plastic cover and main body cover without reinstall ing the working parts 4 Open the stop valve by using the stop adjusting screw and flush out all debris from pipe and connections 5 Shut stop open cover reinstall the working parts replace both covers and tighten This procedure should also be repeated when the system is drained for seasonal use as occurs in ...

Page 7: ...esired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door stepping out of sensor path and making sure yellow L E D is not flashing If sensor locks onto door or wall unit will not flush properly Shorten activation ...

Page 8: ...faces such as metal weaken the signal between the gateway and other devices The LoRa antenna is an omni directional antenna but for best results mount the device so the LoRa antenna is in a vertical position near the top of a wall We recommend conducting a site survey to test the signal strength in different locations before you mount the device Step 4 Mounting the Zurn Gateway The device ships wi...

Page 9: ...eries are dead Replace batteries If the E Z Flush does not begin to function call Cus tomer Service at 1 800 997 3876 Flush Valve Trouble Shooting Guide Problem Corrective Action Status Good posted in plumbSMART and faucet actuation event data not appearing in plumbSMART 2 hours or Device Not Communicating warning or severe alert posted in plumbSMART for all devices 3 hours Step 1 Verify gateway S...

Page 10: ...aucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED is ON If not apply power per Zurn Gateway Insta...

Page 11: ...t 1 0 gal flush P6000 EUA WS1 Water Saving Urinal Kit 1 5 gal flush P6000 EUA WS Full Flush Urinal Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Closet Relief Valve Item 12 P6000 EC13 Flush Connections and Spud Coupling Kits Product No Flush Tube Assembly for Flush Valves Includes Items 15 19 Specify Diameter and Length P6000 A Vacuum Br...

Page 12: ...STRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 11 10 20 C N No NEW Prod Dwg No FV746 ...