INSTALLATION

terminal.  Upon proper connection, test alarm will sound.  Press alarm 

reset to silence.  This indicates proper charger to battery connection.  

CAUTION

 Correct battery hook up is essential for operation of the 

system.  Use nuts supplied with battery and eyelet connectors on battery 

wire leads.  The positive terminal is the larger stud, 3/8" (10 mm) diameter.  

The smaller stud, 5/16" (8 mm) diameter is the negative terminal.  Apply 

grease to the terminals to help prevent corrosion.

8.  Connect the black lead from the pump to the negative (-) battery terminal.   

Connect the white lead from the switch to the positive (+) battery terminal.

9.  Close battery box and secure cover.  

10. 

Plug the control power cord into the 115 V wall outlet.  The primary sump 

pump and the control charger should be on separate circuits.

11.  Reconnect power to primary sump pump.
12.  Optional: a dongle may be used to input a name and number into the 

charger for service information to the end user. Contact Customer 

Support for more information.

13.  Optional: on the bottom of the charger there is a pair of dry contacts to 

signal an auxiliary device of a low battery, high water and reverse polarity 

alarm condition. This simple 2-wire connection is rated at a maximum of 

24 V AC/DC and 0.5 amps.  It can be used with an auto-dialer (such as 

the Zoeller 10-2616), alarm or home security system.  Read the auxiliary 

equipment's documents for further instructions.

1.  Ensure O-ring is properly located on pump discharge. Slide DC pump into 

fitting and tighten the hose clamp (see Figure 2).

2.  The preferred method of installation for backup pumps is shown in Figure 1.  

The installation kit includes one check valve for installing with the backup 

pump discharging into the primary pump outlet pipe.  An additional check 

valve is incorporated in the discharge of the backup pump.

3.  Select location for battery and control charger.  Control charger must be 

within 6' (1.87 m) of a 115 V wall outlet and within 6' (1.8 m) of pump and 

basin.  Connect to a separate circuit, different than the primary pump. 

4. 

Make certain the float switch clamp is tight on the pipe to avoid slippage.  

Ensure that the “off” level of the float is 1" (25 mm) min. above the discharge 

tee of the DC backup pump (see Figure 1).  Position pumps in the sump and 

move float up and down, making sure of free movement without interference 

from  any  obstructions  inside  the  sump  or  lid.    Very  shallow  sumps  may 

require some adjustment to avoid overfilling or backing up of water into the 

sump inlet.  The float switch can be moved on the discharge pipe or the 

rubber stops can be adjusted as necessary.  Cut extra float rod length below 

lower float stop to prevent debris from interfering with float operation (see 

figure 2).

5. 

Mount  DC  control  charger  to  the  wall.    If  more  convenient,  the  control 

charger may be set on a nearby shelf or ledge.  The control charger should 

be located 3' (1 m) or 4' (1.2 m) above the sump.

6.  Connect the green sensor wire to the sensor connector (Figure 3). 

7. 

Connect the leads from the control charger to the battery terminals.  White 

pos. (+) lead to positive terminal and black neg. (-) lead to negative battery 

INITIAL START-UP AND OPERATION

  1.  Test the installation for leaks by running water into the sump allowing for 

normal operation of the primary pump.

  2.  Check the control charger.  The red power on light will be lit when the unit 

is plugged into the 115 V wall outlet. The yellow/green light will indicate 

the condition of the battery.

  3.  Disconnect primary pump before touching any component in the sump pit.
 4. 

Lift float switch.  The DC backup pump will run and the alarm will sound 

after 1 or more seconds.  Lower float switch immediately after alarm has 

started.  Pump is running dry during initial check out for several seconds.   

CAUTION

 Continuous dry running may cause overheating and damage 

the pump seals.  Upon release of the float switch, the pump will shut off. 

Press the reset button to turn the alarm off.

  5.  Complete the final testing of your installation by disconnecting the power 

to 

the primary pump and the control charger by removing the plugs from the 

115 V wall outlets.  Run water into the sump until the DC backup pump is 

activated by the float switch.  Check all connections for leaks.

  6.  Push alarm reset switch when pump is running.  This will silence the alarm.  

The pump will continue to run.

  7.  Reconnect the control charger and your primary pump to the AC wall outlets.  

The primary pump should come on and lower the water level in the sump 

back to the normal operating level and shut off.  Both primary and backup 

systems are now ready for use.

  8.  The battery charged and charging LED’s will alternate during normal 

charging operation.

MAINTENANCE

1.  Inspect and test the system for proper operations at least every 3 months.

 

(a)  Red power on indicator light should be on indicating AC power 

is on.

 

(b)  Unplug primary pump and the control charger from power supply.

 

(c)  Fill sump with water to the “on” level for the DC pump. Allow 

pump to run a few minutes.

 

(d)  The alarm will sound approximately 3 seconds after the pump 

starts to run.

 

(e)  Push alarm reset switch.  The alarm will go off.

 

(f)  Pump will shut off after water level is lowered and the float drops 

to the off position.

2.  Plug the control charger and the primary pump into the wall outlet.

 

(a)   The primary pump will come on and lower the water to the

 

   normal operating level and shut off.

 

(b)   The yellow charging light should be on.  The charger is replacing 

the energy consumed during the test.  The green light will come 

on after the charger has replaced the energy consumed during 

the test.

3.  Add distilled water to battery when necessary per battery manufacturer's 

instructions.  

CAUTION

 Battery acid is dangerous.  Take proper 

safety precautions.  Do not splash the acid.  

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Summary of Contents for ProPak 508-A

Page 1: ... performed by a qualified licensed electrician 9 Pump installation and servicing should be performed by a qualified person 10 Riskofelectricalshock Thesepumpshavenotbeeninvestigatedforuseinswimming pools and marine areas 11 According to the state of California Prop 65 this product contains chemicals known tothestateofCaliforniatocausecancerandbirthdefectsorotherreproductiveharm 12 It is the owner ...

Page 2: ...also have other rights which vary from state to state In those instances where damages are incurred as a result of an alleged pump failure the homeowner must retain possession of the pump for investigation purposes The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts require...

Page 3: ... allow proper clearance for the level control switch es to operate properly 5 DO Always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded circuit DO NOT ever cut splice or damage power cord only splice in a watertight junction box DO NOT carry or lift pump by its power cord DO NOT use an extension cord with a sump pump 6 DO install ...

Page 4: ...CHECK VALVE SCREWS INTO PRIMARY PUMP DISCHARGE HAND TIGHTEN ONLY WEEP HOLE MUST BE VISIBLE FLOAT SWITCH DC PUMP M53 OR M98 PRIMARY PUMP TYPICAL INSTALLATION EXPLODED VIEW OF PUMP SYSTEM OUTLET PUMP PRIMARY 1 25 mm MIN IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R FIGURE 1 FIGURE 2 C...

Page 5: ...If more convenient the control charger may be set on a nearby shelf or ledge The control charger should be located 3 1 m or 4 1 2 m above the sump 6 Connect the green sensor wire to the sensor connector Figure 3 7 Connect the leads from the control charger to the battery terminals White pos lead to positive terminal and black neg lead to negative battery INITIAL START UP AND OPERATION 1 Test the i...

Page 6: ...3766 9 1 1 2 X 2 1 8 long pipe 1 150197 N A N A 10 1 1 2 X 8 3 4 long pipe sch 40 1 010619 019509 019509 11 Fuse 30 Amp AGC 1 012353 012353 012353 CHECKLIST EXPLODED VIEW DC PUMP All installations must comply with all applicable electrical and plumbing codes including but not limited to National Electrical Code local regional and or state plumbing codes etc Not intended for use in hazardous locati...

Page 7: ...a turbulent condition a mixture of air and water may cause a complete or partial air lock and reduce or stop the flow of water in the discharge pipe b Baffle the incoming stream of water to reduce turbulence Diverting water stream against wall of basin usually corrects an air lock problem 7 Water level stays high DC Pump continues to run a Battery is low b If power has been restored and water in s...

Page 8: ...LOW BATTERY ALARM OFF ALARM CONTACTS GREEN LEAD TO FLOAT SWITCH BLACK LEAD WHITE LEAD FIGURE 4 SK2503 FIGURE 5 SK2958 LCD DISPLAY AND KEYPAD FUNCTIONS There are two buttons on the front of the charger The scroll button is used to cycle through the information on the LCD screen The alarm reset button Can be pressed to clear alarm buzzer light and or display Can be held for longer than 3 seconds to ...

Page 9: ...os de los que el estado de California tiene conocimiento de que provocan cáncer malformaciones congénitas u otros daños al sistema reproductor 12 Es responsabilidad del propietario comprobar la batería y la conexión de la batería al menos una vez al mes Las baterías contienen ácido y hay que tener precaución al manipularlas 1 Compruebequelafuentedealimentaciónseacapazderesistirelvoltajequeexige el...

Page 10: ...mba con fines de investigación La bomba de emergencia de CC está diseñada como respaldo a su bomba de sumidero principal durante cortes de energía inesperados o fallas de la bomba principal La bomba de CC los controles electrónicos y todos los elementos necesarios para la instalación vienen incluidos excepto la batería que es suministrada por el usuario El sistema está diseñado para su instalación...

Page 11: ...ierra 4 ASEGÚRESE de que el sumidero es lo suficientemente grande como para permitir un espacio libre apropiado para que los interruptores de nivel funcionen correctamente 5 DESCONECTE siempre la bomba de su fuente de alimentación antes de manipularla SIEMPREconéctelaauncircuitoprotegidoyconectadoatierraporseparado NUNCACORTE empalme o dañe el cable de alimentación solo empalme en una caja de cone...

Page 12: ... A LA DESCARGA DE LA BOMBA PRINCIPAL APRIETE A MANO SOLAMENTE EL ORIFICIO DE DRENAJE DEBE ESTAR VISIBLE INTERRUPTOR DE FLOTADOR BOMBA DE CC BOMBA PRINCIPAL M53 O M98 INSTALACIÓN TÍPICA VISTA EN DESPIECE DEL SISTEMA DE LA BOMBA SALIDA PARA BOMBA PRINCIPAL 25 mm 1 pulg MIN IMPORTANTE EL NIVEL DE APAGADO DE LOS COMPONENTES DEL FLOTADOR DEBE ESTAR POR ENCIMA DE LA BOMBA DE RESERVA DE CC FIG 1 BOMBA DE...

Page 13: ...Pulse el interruptor de reinicio de la alarma para silenciar Esto indica que la conexión del cargador a la batería se realizó correctamente PRECAUCIÓN La correcta conexión de la batería es esencial para el funcionamiento del sistema Utilice las tuercas suministradas con la batería y los conectores de ojete en los cables de la batería El terminal positivo es el perno grande de 1 0 cm 3 8 pulg de di...

Page 14: ... 150197 10 Tubo largo DN40 x 5 5 cm 1 1 2 pulg x 8 3 4 pulg sch 40 1 010619 019509 019509 11 Fusible 30 A AGC 1 012353 012353 012353 LISTA DE VERIFICACIÓN VISTA EN DESPIECE BOMBA DE CC Todas las instalaciones deben cumplir con todos los códigos eléctricos y de plomería aplicables incluyendo pero no limitado a el Código Eléctrico Nacional los códigos de plomería locales regionales y o estatales etc...

Page 15: ... el flujo de agua en la tubería de descarga b Desvié el flujo de entrada de agua para reducir la turbulencia Por lo general desviar el flujo de agua hacia la pared del contenedor para agua corrige el problema de bloqueo por aire 7 El nivel de agua se mantiene alto La bomba de CC sigue funcionando a La batería está baja b Silaalimentaciónseharestauradoyelaguaenelsumideropermanece alta verifique la ...

Page 16: ... reducir las falsas alarmas La luz amarilla de alarma desactivada indica que el timbre está silenciado R R CABLE DE ALIMENTACIÓN CONECTADO A TIERRA LCD ALIMENTACIÓN DE CA DESPLAZAMIENTO CARGADA BOMBA REINICIADA CARGANDO REINICIO DE LAALARMA BATERÍA BAJA ALARMA DESACTIVADA CONTACTOS DE LAALARMA CABLE VERDE AL INTERRUPTOR DE FLOTADOR CABLE NEGRO CABLE BLANCO EL PASADOR DE FIJACIÓN DEBE INSTALARSE DE...

Page 17: ...omme étant cause de cancer et de malformations congénitales ou d autres troubles de l appareil reproducteur 12 Il est de la responsabilité du propriétaire de vérifier la batterie et le raccordement de la batterie au moins une fois par mois Les batteries contiennent de l acide et il est nécessaire de prendre des précautions lors de leur manipulation 1 Assurez vous que l alimentation électrique est ...

Page 18: ...ent résulter d une soi disant défaillance d une pompe le propriétaire doit conserver la pompe à des fins d enquête La pompe de secours à courant continu a été conçue pour remplacer la pompe de puisard principale pendant les pannes d électricité imprévues ou les défaillances de la pompe principale La pompe à courant continu les commandes électroniques et toutes les pièces requises pour l installati...

Page 19: ...rd est assez grand pour permettre le bon fonctionnement de l interrupteur à flotteur 5 Toujours DÉBRANCHER la pompe de la source d alimentation avant de la manipuler ToujourslaBRANCHERsuruncircuitprotégéséparéetquisoitcorrectement mis à la terre NEJAMAIScouper joindreouendommagerlecordond alimentation réaliser une jonction uniquement dans un boîtier de raccordement étanche NE PAS transporter ni so...

Page 20: ...ÉVACUATION DE LA POMPE PRINCIPALE SERRER À LA MAIN UNIQUEMENT LE TROU D ÉVENT DOIT ÊTRE VISIBLE INTERRUPTEUR À FLOTTEUR POMPE À COURANT CONTINU POMPE PRINCIPALE M53 OU M98 INSTALLATION NORMALE VUE ÉCLATÉE DU SYSTÈME DE LA POMPE SORTIE DE LA POMPE PRINCIPALE 25 MM 1 PO MIN IMPORTANT LE NIVEAU D ARRÊT DU FLOTTEUR DOIT ÊTRE PLUS HAUT QUE LA POMPE DE SECOURS À COURANT CONTINU POMPE C C INSTALLÉE EN LI...

Page 21: ...ur du flotteur pour éviter que des débris n empêchent le bon fonctionnement du flotteur reportez vous à la figure 2 5 Montez le chargeur de courant continu au mur Si cela est plus pratique le chargeur peut être posé sur une étagère toute proche Le chargeur doit être situé entre 0 9 et 1 2 m 3 et 4 pi au dessus du puisard 6 Raccordez le fil vert du capteur au raccordement du capteur figure 3 DÉMARR...

Page 22: ...po x 22 2 cm 8 3 4 po 1 010619 019509 019509 11 Fusible 30 A AGC 1 012353 012353 012353 LISTE DE VÉRIFICATION VUE EXPLOSÉE DE LA POMPE À COURANT CONTINU Touteslesinstallationsdoiventêtreconformesauxcodesdelaplomberieetdel électricitéycomprisaucodenationald électricitéaméricain aux codes de la plomberie locale nationale ou de l état etc Système non conçu pour une utilisation dans des zones dangereu...

Page 23: ... Déroutezlefluxentrantd eaupourréduirel agitation Ledétournement du flux d eau contre la paroi de la cuve permet normalement de régler le problème de bouchon d air 7 Le niveau d eau reste élevé La pompe à courant continu continue de fonctionner a La batterie est faible b Si l énergie a été restaurée et que le niveau d eau dans le puisard reste élevé vérifiez la pompe principale Entretenez la batte...

Page 24: ...t chargée prête à fonctionner Le voyant jaune en charge indique le courant qui va à la batterie Le voyant rouge batterie faible clignote lorsque la tension est inférieure à 10 8 V et clignote rapidement lorsqu elle est inférieure à 8 4 V Le voyant jaune de pompe en cycle va clignoter lorsque le flotteur est activé et reste allumé après 3 secondes REMARQUE La pompe est activée lorsque le flotteur l...

Reviews: