The complete wastewater treatment system will typically consist of the Fusion
®
treatment components and a soil absorption
field for final disposal of the liquid effluent. Some states or counties may require the addition of a septic tank before the Fusio
n
®
to
increase the sedimentation chamber capacity and retain more solids. Please see Figure 9 for a typical Fusion
®
system. Variations to
the typical system will be made to suit your particular site and system design needs. Please contact your authorized Fusion
®
installer
or maintenance provider for further information about your system design.
The Fusion
®
alarm panel (see Figure 4) is designed to activate an
audible buzzer and red beacon light on top of the panel if there is a
drop in air pressure, if a high water alarm condition occurs, or if the
blower does not cycle between recirculation and backwash modes
within the preset time. (Note: Alarm panel can only function as
long as there is electrical power supplied to the panel)
You may from time to time check the proper operation of the
alarm panel by toggling the black switch on the side of the panel
to “test”. The buzzer will sound and the red beacon will light as
long as you hold the switch in the test position. Release the switch
for normal operation.
Figure 4
SK2933
The Fusion
®
is designed to treat household type waste and can treat
most common substances introduced into the system. However,
certain harmful substances may reduce the efficiency or stop the
treatment process by reducing or destroying the beneficial bacterial
populations responsible for treatment. In general, if a chemical
substance is considered harmful to humans then it should also be
considered harmful to the Fusion
®
treatment system. If you have any
questions concerning the use of any of these substances, please
contact your Fusion
®
maintenance provider.
The introduction of any
substance on the “Do Not List” into the Fusion
®
will void the warranty.
LEAKY FIXTURES
It is very important to monitor all water fixtures in the home for
leaks and drips and repair them immediately. Excessive water use
may hydraulically overload your Fusion
®
system and reduce its
treatment efficiency. Excessive water use may also overload your
soil absorption field and cause failure.
HIGH USE WATER DEVICES
The draining of hot tubs and swimming pools into your Fusion
®
system could cause hydraulic overloading and may reduce
the treatment efficiency. Please drain these devices to another
location. Contact your local regulatory authorities or authorized
Fusion
®
maintenance provider for more information. The use of
large capacity single fill and drain whirlpool bathtubs may also
cause hydraulic overloading of your Fusion
®
. Please limit the use
of these types of tubs.
The Fusion
®
system is designed to continuously operate
automatically with little direct maintenance from the owner.
Periodically, a check of the blower area is recommended to
ensure no debris obstructs the ventilation or intake areas of
the blower. Also, periodically test the control panel as outlined
under the alarm panel section. The owner should closely monitor
the types and amounts of substances and products used. Water
use should also be closely monitored to ensure proper operation
of the Fusion
®
system.
Periodically, more extensive maintenance must be performed.
Your authorized Fusion
®
maintenance provider will oversee this
service. The name of the maintenance provider can be recorded
on the front of this document and should also be located on
the alarm panel. For more information see the Operation and
Maintenance section of the manual.
The owner should only perform minimal routine maintenance on
the Fusion
®
such as clearing debris from around blower housing
(leaves, snow, and grass clippings). The Fusion
®
should also
be protected from excessive weight such as vehicular traffic.
Trees and bushes should not be planted in close proximity to
the Fusion
®
. The Fusion
®
should be accessible to maintenance
personnel and the riser lids must never be buried.
ALARM PANEL
HARMFUL SUBSTANCES
SYSTEM COMPONENTS
SYSTEM CARE
1 2 3 4 5 6 7 8
TB2
120 VAC L1
INCOMING N
POWER GND
DISNF
ALARM
HIGH WATER
ALARM
BLOWER
*FOR ILLUSTRATION PURPOSES ONLY*
REFER TO SCHEMATIC LOCATED IN
PANEL FOR INSTALLATION
BLOWER FOR LARGE ZFL FUSION MODELS
GND LUG
TRANSFORMER
TIMER SWITCHING VALVE
S1
R1
E
S
R