Thank you for choosing a Fusion

®

 Series Treatment System. High-quality 

workmanship and easy maintenance have been incorporated into the 

Fusion

®

 system. The system will provide years of trouble-free service 

when maintained according to the manufacturer’s recommendations. 

Please read this manual in its entirety before using the Fusion

®

 and follow 

all instructions to ensure proper operation. Keep this manual for future 

reference along with other important onsite documents. Should further 

assistance be necessary, please contact Zoeller Pump Company at 1-800-

928-7867.

Warning Labels

You will find warning labels on the Fusio

n

®

, riser lids, blower, and the alarm 

control panel. It is very important to follow the information on these labels to 

ensure your safety. Please do not remove these labels.

1. 

DO NOT attempt to service the Fusion

®

 unit yourself. Contact your 

authorized maintenance provider for all service related issues.

2. 

There are buried electrical cables and piping near and around the 

Fusion

®

. Please consult with your authorized maintenance provider to 

locate these utilities before excavation.

3. 

DO NOT bury or cover the Fusion

®

 lids with soil or other debris. This is 

necessary to allow access for operation and maintenance of the unit.

4. 

The Fusion

®

 blower must be unobstructed and vented for proper 

operation. Care must be taken that no grass clippings or other materials 

accumulate on or around the blower and block ventilation.

5. 

DO NOT place heavy objects over the Fusion

®

 or drive heavy equipment 

over the Fusion

®

, as damage may occur. Damage of this kind is not 

covered by the warranty.

6. 

DO NOT plant trees within 15 feet (4.6 m) of the Fusion

®  

Series Treatment 

System.

Fusion

®

 Series Treatment Systems

SECTION: C3.10.142

CL

0169
0122

Supersedes

0517

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

OWNER'S MANUAL

Large Commercial Models 

ZFL-2800 & ZFL-4000

Manufacturer warrants, to the purchaser and subsequent owner 
during the warranty period, every new product to be free from defects 
in material and workmanship under normal use and service, when 
properly used and maintained, for a period of two years from date of 
purchase by the end user.  No allowance will be made for shipping 
charges, damages, labor or other charges that may occur due to 
product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for 
any material or product that has been disassembled without prior 
approval of Manufacturer, subjected to misuse, misapplication, 
neglect, alteration, accident or act of nature; that has not been installed, 
operated or maintained in accordance with Manufacturer's installation 
instructions; that has been exposed to outside substances including 
but not limited to the following:  sand, gravel, cement, mud, tar, 
hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), 
or other abrasive or corrosive substances, wash towels or feminine 
sanitary products, etc. in all pumping applications.  The warranty set 
out in the paragraph above is in lieu of all other warranties expressed 
or implied; and we do not authorize any representative or other person 

to assume for us any other liability in connection with our products.
Contact  Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  
40211, Attention: Customer Support Department to obtain any needed 
repair or replacement of part(s) or additional information pertaining 
to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR 

SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR 

BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND ANY 

IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE 

AND OF MERCHANTABILITY SHALL BE LIMITED TO THE 

DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied 
warranty, so the above limitation may not apply to you. Some states 
do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

LIMITED WARRANTY

Fusion

®

 Model:

 

 

ZFL-2800 

  

 

ZFL-4000

Serial No. 

____________________________________

Installing Contractor 

____________________________________

Phone Number 

____________________________________

Installation Date 

____________________________________

Maintenance Provider’s Name 

_____________________________

Phone Number 

____________________________________

Limited Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Process Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
System Components and Care. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation and Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Blower Installation And Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Aeration Chamber Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Blower Inspection and Maintenence   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

TABLE OF CONTENTS

Register your 

Zoeller Pump Company Product 

on our website:

http://reg.zoellerpumps.com/

Summary of Contents for Fusion Series

Page 1: ... years from date of purchase by the end user No allowance will be made for shipping charges damages labor or other charges that may occur due to product failure repair or replacement This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer subjected to misuse misapplication neglect alteration accide...

Page 2: ...rom the liquid In the second chamber plastic media with large surface areas are used to increase contact between water and beneficial bacteria to optimize treatment A small linear air blower is used to move air oxygen into the third chamber for the aerobic process The final effluent leaving the system will have been treated to secondary quality effluent HOW A FUSION SERIES TREATMENT SYSTEM WORKS F...

Page 3: ...ous nitrogen The gaseous nitrogen then escapes to the atmosphere 3 Aeration Chamber The aeration chamber consists of an aerated upper section and a filter media lower section The chamber is filled with hollow cylindrical filter media 0 6 inch diameter 15 mm and 0 55 inches long 14 mm Biological treatment takes place on the filter media surface Aeration is continuous Residual suspended solids are c...

Page 4: ...repair them immediately Excessive water use may hydraulically overload your Fusion system and reduce its treatment efficiency Excessive water use may also overload your soil absorption field and cause failure HIGH USE WATER DEVICES The draining of hot tubs and swimming pools into your Fusion system could cause hydraulic overloading and may reduce the treatment efficiency Please drain these devices...

Page 5: ... reconnect power to either the blower or alarm panel once it has been submerged Immediately contact your authorized Fusion maintenance provider to inspect the Fusion the blower and the alarm panel Your maintenance provider will repair or replace the components as needed Fusion Series systems are compact efficient and designed to be installed in a typical residential light commercial environment Th...

Page 6: ...amp soil around perimeter of the unit as it is backfilled to stabilize the unit and to reduce settling 7 Finalize backfill with a mounded contour so that surface water is shed away from the unit Under no circumstances should surface water be allowed to accumulate around unit 8 CAUTION MAXIMUM soil burial depth over the unit is 36 inches 914 mm EXCAVATION AND INSTALLATION BACKFILLING COLD WEATHER I...

Page 7: ...er by 6 inches in height Do not install more than two riser heights together for a maximum of 12 inches burial depth Prepare risers by applying two complete circular beads of silicone or other like sealant around riser flange in order to seal risers and make the installation watertight Install the 24 inch diameter riser onto the already installed riser adapters with the provided stainless steel sc...

Page 8: ...on lines 8 Attach the small diameter black air tubing included in the blower box to barbed fitting on PVC tee Black air tubing and blower cord should be routed to the control panel through conduit Attach the black air tubing line to the air pressure sensor barbed fittings in the panel Figure 10 If air tubing is not connected to backwash and recirculation lines the panel will alarm 9 Connect the re...

Page 9: ...ncrete Volume W H Concrete Volume W H Concrete Volume W H Concrete Volume FT FT FT3 CY FT FT FT3 CY FT FT FT3 CY FT FT FT3 CY ZFL 2800 2 8 3 0 432 16 2 7 2 8 370 14 2 6 2 5 323 12 2 3 2 10 334 13 ZFL 4000 3 0 3 0 531 20 3 0 2 6 443 16 2 10 2 5 400 15 2 6 2 11 416 16 Model 24 Cover 30 Cover 36 Cover W H Concrete Volume W H Concrete Volume W H Concrete Volume FT FT FT3 CY FT FT FT3 CY FT FT FT3 CY Z...

Page 10: ...electrical codes 2 The blower should be directly wired into the alarm panel The alarm panel must be located in a dry location that is accessible for maintenance Please see the wiring diagram and instructions enclosed with the alarm panel 3 Make certain the timer within the control panel is set to the proper time The timer unit display should be set to 10 hours and the timer dial needle set to 3 6 ...

Page 11: ...ng valve control pad Set the backwash flow rate by adjusting the gray sludge transfer valve 4 Use Table 5 to determine the typical setting for each Fusion model Measuring the flow rate Measure the actual backwash flow rate at the outlet of the sludge return pipe in the first chamber the same way the recirculation flow rate is measured Adjust the gray sludge transfer valve 4 if necessary to obtain ...

Page 12: ...es 1 Transparency Measures the ability of the water to transmit light Using the ladle fill the transparency tube with a water sample collected from the clean water storage chamber Looking down through the water column slowly drain the transparency tube using the valve on the flexible hose until you can first distinguish between the black and white colors on the secchi disk in the bottom of the tub...

Page 13: ...olor remnants of digestion are often yellowish in color White sometimes present after new construction often due to drywall mud PART B Anaerobic Chamber collect samples from the outlet baffle of the anaerobic chamber to be used for the following analyses 1 Transparency A transparency reading more than 20 cm is preferred 2 Scum Should not be present unless recirculation and orbackwashrateistoohigho...

Page 14: ...aeration line after the switching valve as shown in Fig 20 Gradually open the water faucet and introduce water into the system Rotate valve 1 back and forth from the 0 to the 100 position several times to flush Turn off the water remove the water line and reconnect the airline to the blower Set valves 1 and 2 back to the appropriate positions See Recirculation Flow Adjustment pg 10 C Cleaning the ...

Page 15: ...ING 1 Odor Offensive odors are often the result of insufficient or inappropriate bacterial growth Causes may include a young or unestablished system insufficient air introduction or the addition of detrimental chemicals or poisons into the system Ensure the blower and air delivery systems are functioning Check with the homeowner regarding chemical use and disinfection habits Check all risers and l...

Page 16: ...MAINTENANCE PUMPING AS NEEDED Figure 21 Pump out procedures Step 1 Remove the scum Step 2 Remove the sludge 1 2 Sedimentation separation tank Vacuum Step 1 Remove the scum Step 2 Remove the sludge on the filter media Step 3 Remove the sludge under the media while washing the filter with tap water 1 Anaerobic filter tank Vacuum Tap water 2 3 ATTENTION Remove the scum first If you remove the sludge ...

Page 17: ...17 Copyright 2022 All rights reserved ...

Page 18: ... and pull the rubber elbow away from the discharge port of the diaphragm housing Carefully use a small flat bladed screw driver to unbond uncouple the rubber tube from the discharge port then pull it away See Figure 29 6 Next pull the diaphragm housing away See Figure 30 7 Unscrew the hex nut at the center of the diaphragm and proceed to pull the diaphragm from the magnetic bar See Figure 31 8 If ...

Page 19: ... 94 100 Weight in Pounds 2425 3748 Lids and Access 24 Diameter 4 4 Blower Information Alita AL 250 1 Alita AL 300 1 Switching Valve P N 151438 1 1 Air Line Size s 3 4 Recirculation 1 1 1 Backwash 1 1 Inlet Outlet Information Influent Invert inches 21 21 Effluent Invert inches 28 28 Inlet Outlet Pipe Size Inches 4 4 Blower Details Voltage Amps Sound dB Air Flow L min Weight Alita AL 250 120 3 7 46 ...

Page 20: ...ight 2022 All rights reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoellerpumps com ...

Reviews: