  STEP 4 

OPERATIONAL TEST OF COMPLETE SYSTEM

  4.1)  With the cover removed, temporarly connect the discharge pipe.

 

 

NOTE:  At this point, the pit is filled with water, and the float 

is in the “on” position.

  4.2)  Plug the float switch into the outlet and the pump plug into the float 

plug (refer to Figure 4.2).  The pump should immediately empty 

the pit. If the pump does not turn on, continue filling the pit with 

water.

  

NOTE:  If the pump does not turn “on/off”, and the float is in 

the vertical position and/or submerged, refer to the trouble

-

shooting guide at the end of this manual.

  4.3)  Verify that the pump cycles on and that the desired “pump-down” 

range is acceptable.

  4.4)  Repeat manual cycling of pump as necessary to insure proper 

operation.

  4.5)  Unplug the pump, disconnect the discharge pipe, replace cover 

and complete the installation as shown in Figure 4.2.

If the above check list does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must be by 

Zoeller Authorized Service Stations.

TROUBLESHOOTING GUIDE

  ELECTRICAL PRECAUTIONS-

 Before servicing a pump, always shut off the main power breaker and then unplug the pump - making sure you are not standing in 

water and are wearing insulated protective sole shoes.  Under flooded conditions, contact your local electric company or a qualified licensed electrician for disconnecting electrical service 

prior to pump removal.  

CAUTION

  Submersible pumps contain oils which becomes pressurized and hot under operating conditions - 

allow 2½ hours after disconnecting before attempting service.

NOTE:  If  too little water is removed, adjust the tether length per STEP 2.

 IMPORTANT!  Repeat Steps 3 & 4 if tether length is adjusted.

Figure 4.2

CONDITION

 

COMMON CAUSES

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal 

bound mechanically, defective capacitor or relay when used, motor or wiring shorted.  Float as-

sembly held down.  Switch defective, damaged, or out of adjustment.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound 

mechanically, defective capacitor or relay, motor shorted.

Check valve stuck or none installed in long discharge line, overload open, level switch(s) defec-

tive, sump pit too small.

Debris under float assembly, float  bound by pit sides or other obstruction, switch defective, dam-

aged or out of adjustment.

Check strainer housing, discharge pipe, or if check valve is used vent hole must be open.  Dis-

charge head exceeds pump capacity.  Low or incorrect voltage.  Incorrect motor rotation. Capacitor 

defective. Incoming water containing air or causing air to enter pump.

Increased pipe friction, clogged line or check valve.  Abrasive material  and adverse chemicals 

could possibly deteriorate impeller and pump housing.  Check line.  Remove base and inspect.

A. Pump will not start or run.

B. Motor overheats and trips overload or blows fuse.

C. Pump starts and stops too often.

D. Pump will not shut off.

E. Pump operates but delivers little or no water.

F. Drop in head and/or capacity after a period of use.

SK2070

  STEP 3 

VISUAL INSPECTION OF COMPLETE SYSTEM

  3.1)  With the pit cover removed and the pump unplugged, fill the pit with water.

  3.2)  As the pit is filling, verify that the float path is not obstructed by the wall or any other object.

 

  3.3)  If the float is obstructed, remove obstruction and/or adjust the tether length per STEP 2. 

Summary of Contents for 2000 Series

Page 1: ... do not deliver sufficient voltage to the pump motor and they could present a safety hazard if the insulation were to become damaged or the connection end were to fall into a wet or damp area 3 Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper capacity A separate branch circuit is recommended sized according to the National Electrical Code for the cu...

Page 2: ... use and service when properly used and main tained for a period of one year from date of purchase by the end user or 18 months from date of original manufacture of the product whichever comes first Parts that fail within the warranty period one year from date of purchase by the end user or 18 months from the date of original manufacture of the product whichever comes first that inspections determ...

Page 3: ... 4 5 6 7 8 9 10 11 12 13 14 15 17 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 TETHER LENGTH INCHES DIMENSION A MIN TETHER LENGTH DIMENSION B PUMPING RANGE INCHES 20 21 22 23 24 25 26 27 16 4 10 2 cm 6 15 2 cm 8 20 3 cm 10 25 4 cm 12 30 5 cm 14 35 6 cm 16 40 6 cm 26 66 0 cm 22 55 9 cm 18 45 7 cm 14 35 6 cm 10 5 26 7 cm 8 20 3 cm 6 5 16 5 cm Tether B Range A STEP 2 INSTALLATION OF THE VARIABLE...

Page 4: ... service NOTE If too little water is removed adjust the tether length per STEP 2 IMPORTANT Repeat Steps 3 4 if tether length is adjusted Figure 4 2 CONDITION COMMON CAUSES Check fuse low voltage overload open open or incorrect wiring open switch impeller or seal bound mechanically defective capacitor or relay when used motor or wiring shorted Float as sembly held down Switch defective damaged or o...

Page 5: ...rica de la bomba esté equipado con fusibles o interruptores de circuito de capacidad adecuada Se recomienda un circuito auxiliar del tamaño de acuerdo a los códigos eléctricos para la corriente que se muestra en la etiqueta de nombre de la bomba 4 Prueba de puesta a tierra Como medida de seguridad cada tomacorriente debe verificarse para puesta a tierra usando un analizador de circuitos el cual in...

Page 6: ...XPRESA Algunos estados no permiten limitaciones en la duración de una garantía implícita de forma que la limitación anterior podría no aplicar a usted Algunos estados no permiten la exclusión o limitación de daños incidentales o emergentes de forma que la limitación o exclusión anterior podría no aplicar a usted Esta garantía le otorga a usted derechos legales específicos y podría tener otros dere...

Page 7: ...ENSIÓN A LONGITUD MÍNIMA DE SUJECIÓN DIMENSIÓN B RANGO DE BOMBEO PULGADAS 20 21 22 23 24 25 26 27 16 10 2 cm 4 pulg 15 2 cm 6 pulg 20 3 cm 8 pulg 25 4 cm 10 pulg 30 5 cm 12 pulg 35 6 cm 14 pulg 40 6 cm 16 pulg 66 0 cm 26 pulg 55 9 cm 22 pulg 45 7 cm 18 pulg 35 6 cm 14 pulg 26 7 cm 10 5 pulg 20 3 cm 8 pulg 16 5 cm 6 5 pulg Sujeción B Rango A PASO 2 INSTALACIÓN DEL INTERRUPTOR DE FLOTADOR DE NIVEL V...

Page 8: ...recorrido del flotador no quede obstruido por la pared o cualquier otro objeto 3 3 Si se obstruye el flotador elimine la obstrucción y o ajuste la longitud de sujeción según el PASO 2 Copyright 2015 Zoeller Co Todos los derechos reservados LISTA DE VERIFICACIÓN DE SERVICIO Si la lista de verificación arriba mencionada no revela el problema consulte con el departamento de Product Support No intente...

Page 9: ... est équipé de fusibles ou de disjoncteurs de capacité appropriée Il est recommandé d installer un circuit indépendant de capacité suffisante conforme aux codes électriques nationaux pour la capacité indiquée sur la plaque d identification de la pompe 4 Vérification de la mise à la terre Pour des raisons de sécurité il faut vérifier la terre de chaque prise électrique en utilisant un analyseur de ...

Page 10: ...pas les limitations de la durée de la garantie implicite et il est possible que cette limitation ne s applique pas Certaines provinces ne permettent pas l exclusion ou la limitation des dégâts secondaires ou indirects et il est possible que cette limitation ou exclusion ne s applique pas Cette garantie vous donne des droits spécifiques reconnus par la loi et vous pouvez également avoir d autres dr...

Page 11: ...8 19 LONGUEUR DE L ATTACHE POUCES DIMENSION A LONGUEUR MINIMUM DE L ATTACHE DIMENSION B PLAGE DE LA POMPE POUCES 20 21 22 23 24 25 26 27 16 ÉTAPE 2 INSTALLATION DE L INTERRUPTEUR À FLOTTEUR À NIVEAU VARIABLE CLAPETS ANTIRETOURS TROU D ÉVENT TUYAU D ÉVACUATION BIEN ATTACHER LE CORDON AU TUYAU POMPE COUVERCLE TUYAU D ÉVENT CIRCUIT TERRE CORRECTEMENT GFCI SK2065 DÉTAIL A 10 2 CM 4 PO MINIMUM SK2067A ...

Page 12: ...au 3 2 Au fur et à mesure du remplissage vérifier que le mur ou un autre objet n empêche le mouvement du flotteur 3 3 Si le flotteur est coincé retirer l obstruction ou ajuster la longueur de l attache comme indiqué à l ÉTAPE 2 Copyright 2015 Zoeller Co Tous droits réservés LISTE DE VÉRIFICATIONS POUR L ENTRETIEN Si les vérifications ci dessus ne résolvent le problème consulter l usine Ne pas essa...

Reviews: