MAINTENANCE AND FUNCTION /
TOOLHEADS
57
To change extruder temperature settings:
To change extruder callibration:
Open config file with notepad.
1
Open config file with notepad.
1
Change:
2
Change:
2
If you exchange extruder to another device that measures temperature
(is equipped with thermistor),
make sure to verify BETA values of this thermistor.
They are specified on the device, or in it's documentation. If unsure - ask us.
If beta is different, you have to change it in config file, and restart the machine. Otherwi-
se - the readout might vary and create unwanted effects, such as overheating the plastic.
temperature_control.hotend.beta XXX
extruder.hotend.steps_per_mm YYY
steps_per_mm 100
steps_per_mm 400
(Where XXX is the value)
(Where YYY is the value)
For 175 extruder
For 3.00 extruder
EXAMPLES:
Currently (when using new firmware) you can use 'Select Toolhead' menu in
LCD panel instead of steps above.
!