158
Press the
OK
key.
The Advanced Options menu will appear;
Adv Option
▲
▼
Clear Admin Pri
Show Score N
►
Match Thr 45
Scroll with the
▲
/
▼
keys and place the cursor ( ) alongside Match Thr.
Press the
OK
key.
Notice the
45
in Match Thr becomes highlighted;
Adv Option
▲
▼
Clear Admin Pri
Show Score N
►
Match Thr
45
Use the keypad or scroll
▲
/
▼
keys to change the threshold setting.
Lessening the threshold lessens the sensitivity of the sensor when reading
“difficult” fingerprints.
If the F707/708 is having difficulty reading most users’ fingerprints, then
consider lessening the threshold in 5-unit increments until the vast
majority of users’ fingerprints can be read consistently.