806834 v1.02 07.21 G5 Online install instructions and user guide
94
USER GUIDE
3.7.7 Advanced settings
Advanced settings 1
Periodic pulse reduced cavitation mode
• Sends 2 electric pulses every 5 minutes to the
pump.
• This prevents the build up of air bubbles inside the
pump to ensure an even flow of hot water at the
tap.
12:12 PM
ADVANCED SETTINGS 1
Periodic Pulse Reduced Cavitation Mode
Hot setpoint must be < 98°C to disable
Pre-Pulse Reduced Cavitation Mode
Adds slight delay to boiling dispense
Power Pulsing Mode
Hot setpoint must be < 98.5°C to disable
Pre- pulse reduced cavitation mode
• Pulses immediately before boiling dispense to
prevents the build up of air bubbles inside the
pump to ensure an even flow of hot water at the
tap.
• There will be a 150 millisecond delay before water
is dispensed.
Power pulsing mode
• Applies a closer tolerance to the set temperature,
to ensure hot water is maintained as closely as
possible to the set point.
• In rare occurrences, enabling this feature may
cause the tap lights to flicker during the boiling
water recovery period.
[ ]
[ ]
Section 3 Command Centre Screen
Advanced settings 1