806834 v1.02 07.21 G5 Online install instructions and user guide
8
Water supply pressure requirements
UK models: A pressure limiting valve must be fitted for mains water pressures above the
maximum limits stated above, in accordance with local plumbing regulations.
All other models (except UK): HydroTaps have an internal pressure limiting device to reduce
the maximum mains regulated pressure, protecting the system against pressure surges above
500 kPa.
!
Component
Min - Max pressure, kPa (bar)
Australia
UK
HydroTap
170 (1.7) - 700 (7.0)
170 (1.7) - 500 (5.0)
Sparkling HydroTap
250 (2.5) - 700 (7.0)
250 (2.5) - 500 (5.0)
Vented Mixer Tap
300 (3.0 ) - 700 (7.0)
200 (2.0 ) - 500 (5.0)
Booster
200 (2.0) - 700 (7.0)
200 (2.0) - 500 (5.0)
Lime scale filter
200 (2.0) - 700 (7.0)
200 (2.0) - 500 (5.0)
Water supply connection
1/2” BSP (G1/2)
Electricity supply requirements
220-240V 50Hz AC (for power requirement see table above).
220 60Hz AC.
Booster specification
Specification
Rating
Power 230V 50/60Hz
2.20 kW
Power 240V 50/60Hz
2.40 kW
Flow rate
1.2 L/m
Technical data
Country
Without Booster
With Booster
Australia
1x 220 - 240V AC 10A socket
2x 220 - 240V AC 10A sockets
UK
1x 220 - 240V AC 13A socket
2x 220 - 240V AC 13A sockets