3.7.2 Temperature settings
Boiling / Chilled set point
Chilled models
• Default set point: 5-9ºC Commercial, 6-10ºC
Residential.
• Scroll to select alternatives.
Boiling models
• Default set point: 98ºC Set point range: 68-
100ºC.
• Operation: Within 1-2ºC of set point.
• Note
Boiling water delivery rate will be
affected with a higher temperature setting.
Up to 6% less energy in standby is consumed
with a 98ºC set point, rather than 100ºC.
• A warning icon will appear when setting
boiling set point temperatures that are
subject to pump cavitation.
[ ]
[ ]
Chilled models
• Default set point: 3-6ºC Commercial, 3-7ºC
Residential.
• Scroll to select alternatives.
• Adjust as required.