Zip Hydroboil Plus - Installation & Operating Instructions - 85680 - February 2004
Page 12 of 16
Information for Ambient Chilled Conversions
Hydroboil Plus Series 2003
Models: 3 Litre, 5 Litre, and 7.5 Litre. All filter configerations.
Removal of case assembly
NOTE
: All procedures described below require the special key supplied with
your Hydroboil Plus.
1. Use the key supplied with your Hydroboil Plus heater and turn the chrome
plated locking ring anti-clockwise to remove it. The button will also be
released at this point.
2. The tap body retaining ring is now exposed, using the key, turn the ring
anti-clockwise and remove it. This now allows the case to be removed.
3. The removal of the case assembly will expose the chilled / cold outlet tap
assembly and access to the tap cartridge.
Cartridge Removal
To remove the tap cartridge use the key so the two (2) prongs locate in the
cartridge retainer screw. This is also to be turned anti-clockwise to remove it.
Once removed, the tap cartridge can be extracted from the tap body.
Flow Adjustment
Adjustment for flow from the chilled / cold outlet is achieved by turning the
flow adjuster located at the end of the cartridge with a flat blade screwdriver.
Turning clockwise increases flow, where turning anti-clockwise decreases flow.
Re-assembly
of the tap is the reverse of the dismantling proceedure. Ensure
when locating the cartridge assembly in the tap body the transfer pipes on the
base of the cartridge slip into their locating holes in the tap base. Failure to do
this will cause damage to the cartridge.