Zip Hydroboil Plus - Installation & Operating Instructions - 85680 - February 2004
Page 9 of 16
Following remedial service the earthing continuity of the heater must be
checked by a qualified technician using an appliance tester, or continuity tester
of accuracy Class 5 or better. Class 5 denotes an accuracy of 5% full scale
deflection.
1. Isolate power supply.
2. Set meter to 0 ohm with leads connected together.
3. Connect one test lead to the earth pin on the three pin plug.
4. Connect the other test lead to a bare patch of metal (preferably on the edge)
of the top of the cover, then to the front cover of the unit, and then to the tap
top under the plastic paddle. This can be achieved by inserting the probe up
from behind the paddle without losing water.
Warning-
the water may be boiling - show extra care.
5. Test that in every instance the electrical resistance does not exceed 1 ohm.
Earthing Continuity Verification
TESTER
CONNECT BETWEEN THE
EARTH ON THE THREE PIN
PLUG OR EARTH CABLE
AND EXPOSED METAL
PARTS AS PER POINT 4 AT
RIGHT
Symptom
Possible Cause
Solution
Fails to dispense water.
Water isolating valve turned off.
Blocked filter, blocked meter tube,
blocked strainer, jammed ball valve
assy, airlock in transfer tube.
Check water supply valve.
Contact Zip Service Provider
Water not boiling.
No power.
Overload Tripped, faulty element, faulty
thermostat.
Check power supply.
Contact Zip Service Provider
Runs out of boiling water and fails to
refill.
Outlet tap drips.
Overflow from vent.
Excessive steam from vent.
Power “on” but no heat.
“Power on”, “Boiling water” light on
but no heat.
No heat, no”Power on” light.
Overload repeatedly tripping with
excessive steam.
Overload repeatedly tripping without
excessive steam.
No water from ambient button.
Internal adjustment.
Contact Zip Service Provider
Problem Solving