40
DDOC00416 / a
EN / 2020-08-19
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
+49 7844 9138 0
●
+49 7844 9138 80
●
www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
2-jaw parallel gripper, electric, HRC-01/-02 series
13.2 Replacing the safety fuse
INFORMATION
The fuse assembly is sealed in the vicinity of the safety fuse when shipped from the factory.
The sealing must be removed to replace the safety fuse.
The safety fuses vary depending on the model series:
HRC-02-093390: 315 mA - super quick acting, Püschel (105.000 series)
HRC-02-093677: 315 mA - super quick acting, Püschel (105.000 series)
HRC-02-093695: 315 mA - super quick acting, Püschel (105.000 series)
HRC-02-101487: 800 mA - super quick acting, Püschel (105.000 series)
HRC-02-101528: 800 mA - super quick acting, Püschel (105.000 series)
HRC-02-101903: 800 mA - super quick acting, Püschel (105.000 series)
If any safety fuses not sold or authorized by Zimmer GmbH are used, the function of the gripper cannot
be guaranteed.
Unauthorized replacement of the safety fuse may result in complications, as special installation equip-
ment and tools are sometimes required.
►
Opening the gripper without authorization will void the warranty.
Replacement of the safety fuse must be carried out by Zimmer Customer Service!
Ö
Warranty and disclaimer
CAUTION
The replacement of the safety fuse must only be performed by personnel qualified to do so
►
Risk of accident and/or injury