7.4 Installing the power supply
7.4.1 Installing the wiring
►
Connect the supply cable to the gripper and the control system.
Ö
You can find the corresponding supply cable on our website.
INFORMATION:
The cables that are used by Zimmer GmbH feature a minimum bending radius of 10 x the outer diameter.
This bending radius must not be undershot!
►
All IO-Link cables that are installed in the grippers have an outer diameter of 5 mm and thus
have a bending radius of 50 mm.
►
Freely suspended cables must be secured to prevent excessive motion loads or pinching.