5.2 Connection
Representation with standard connecting cables
07.11.2013
v_anschl_ecblue_baugr_b_ip20.vsd
1
2
3
1
Connection control (Molex-micro-
fi
t 3.0 8-pole, 43045-43045)
2
Connection line (AMP 3-pole MATE-N-LOK, 350789-3)
3
Do not loosen the safety screws from the housing!
Control: hose cable 8 x 0.14 mm
2
(26 AWG) comparable LiYY-OB, length approx. 1.1 m *
RJ45 (8 pole)
Motor side
06.11.2013
i_ecblue_B_ip20_control.eps
BK
BN
OG
BU
YE
VT
GN
RD
8 = BU, 7 = YE, 6 = OG, 5 = BN, 4 = BK, 3 = VT, 2 = GN, 1 = RD
Line: hose cable 3 x 1.0 mm
2
(18 AWG) comparable LiYY-JB, length approx. 1.1 m *
Motor side
01.08.2013
i_ecblue_B_ip20_netz.eps
BN
BU
GNYE
GNYE
BU
BN
*
The type and length of the connecting cable may vary depending on the version
Assembly instructions
ECblue
Electrical installation
L-BAL-F056-GB 2022/45 Index 005
Part.-No. 00700562-GB
20/44