2. Cot menu
The
cot menu
is opened from the supply air temperature display with the
▼
-key. The size of the menu depends
on the number of cots in the alarm system. The settings for overtemperature and undertemperature can be
checked and set for a maximum of 32 cots.
Fresh air temperature dis-
play
21:04 Freshair
▼
▲
Cot 1
P
Alarm ON / OFF 1
▼
▲
▼
▲
Cot 2
P
Alarm ON / OFF 2
▼
▲
▼
▲
Cot 3
P
Alarm ON / OFF 3
▼
▲
3. Installation menu
The
installation menu
“
ALARMcon Setup
”
is primarily for basic settings that have to be made during start-up.
These settings should only be made with exact knowledge of the device function and system constellation. To
protect this menu against unintentional changes, PIN 0010 must be entered in the Info menu.
Once this menu is open, the PIN-Protection is no longer active for approx. 15 minutes after the last key
con
fi
rmation.
Otherwise the operation in the Installation menu does not differ from that of the other menus.
To exit the installation menu, press the key
|
Esc
|
.
Fresh air temperature dis-
play
21:04 Freshair
Procedure:
1. Press the
P
-key when in the overview to show
the
“
PIN
”
menu item.
2.
Press the P
-key, the
fi
rst digit
“
0
”
fl
ashes.
3.
Press P
-key 2 x until the third digit
“
0
”
fl
ashes,
then set with the
▲
-key to
“
1
”
and con
fi
rm with
P
-
key.
4. For the fourth digit con
fi
rm
fl
ashing
“
0
”
with
P
-key
=>
|
0010
|
is complete.
5.
Press the P
-key, the
fi
rst menu group
“
ALARMcon Setup
”
appears in the installation
menu. The
“
Installation
”
menu is opened, (the
triangle points to the tool icon = Installation).
↑
|
ESC
|
P
↓
PIN input
P
PIN 0010
▼
▲
ALARMcon Setup
P
Control sys. Master
▼
▲
▼
▲
Alarm input D1
P
D1
▼
▲
Operating Instructions
ALARMcon
–
model series UTE-32A-L
Controls and Menu
L-BAL-E251-GB 1542 Index 002
Part.-No. 00163281