Vo lta g e
C u rre n t
± 0.2 % of range
± 0.2 % of range
Frequency
0.15% of mid frequency
Active Energy
± 0.2 % of range
± 0.2 % of range
Active Power
± 0.2 % of range
Re- Active Power
± 0.2 % of range
Apparent Power
Re - Active Energy
Apparant Energy
± 0.2 % of range
Power Factor
± 1 % of Unity
Angle
± 1 % of range
Analog Output
± 1 % of Output end value
Total Harmonic Distortion
± 1 %
Accuracy 0.2:
± 0.2 % of range
Neutral Current
± 4 % of range
Reference conditions for Accuracy :
0
23 C
0
+ 2 C
50 or 60Hz 2%
±
Reference temperature
Input frequency
69