Explanation for 4 X register :
Address
Parameter
Description
Demand Reset is used to reset the Demand parameter. A value
of zero must be Written to this register to reset the Demand
period. Writing any other value will return an error.
40001
Demand Reset
40003
Demand Period Demand period represents demand time in minutes. The
applicable values are 8,15,20 or 30. Writing any other value will
return an error.
40005
40007
System Voltage This address is read only and displays System Voltage
40009
System Current This address is read only and displays System Current
40013
Pulse Width
of Relay
This address is used to set
pulse width
of the Pulse output.
Write one of the following values to this address:
60
:
60 ms
100
:
100 ms
200
:
200 ms
Writing any other value will return error .
40015
Reset Energy
Counter
This address is used to reset the Energy Counter.
Write zero value to this register to reset the energy counter.
Writing any other value will return an error.
48
Energy display
on Modbus
This address is used to set energy display on MODBUS in
Wh,
K
w Write one of the following value to this address.
1
=
3
= Energy in M
W
h.
Wh & M h.
Energy in Wh. 2 =
Energy in KWh.
40017
Run/On Hour &
Interruption
reset
This address is used to reset the Run/On hour & number
of Interruption . Write zero value to this register to reset
the Run/On hour & number of Interruption.
Writing any other value will return an error.