31
4.11 Chopper
Fig. 36
Drive
(E) Ventilator
(K) Inspection glass
(W) Anti-wrap guard
Check the oil level regularly
The chopper bearing is fitted with a lifetime lubrica-
tion system and is maintenance-free.
Fig. 37
Arrangement of the chopper blades
The chopper blade (M) is to be fitted above the
blade carrier using the original bushing.
The screw (S) must be tightened in accordance with
the prescriptions of the operating instructions on
page 53.
Switch off the motor and activate the lowering
lock before commencing any work on the ma-
chine.
Caution: Blades over-travel for two
minutes.
Wear the corresponding protective cloth-
ing.
Fig. 38
Switching the chopper on and off
Unscrew the holding screws (H) and move the lever
to the desired position (it may be necessary to turn
the chopper until the coupling snaps into place) then
tighten the holding screws.
Switch off the motor and activate the
lowering lock before commencing any
work on the machine.
K
E
W
M
S
H