Water Quality
The right water quality is important for conditioning the coolant. Clear, clean water within the following
analysis values should always be used:
Specifications of the water quality are made by the local water board.
The water must be conditioned if it deviates from the analysis values.
Cooling System Corrosion Protection Agent
Caution:
Health damaging nitrous amines form when nitritebased cooling system corrosion
protection agents are mixed with amine-based agents!
Note:
z
Cooling system corrosion protection agents must be disposed of in an environmentally
friendly way.
z
Observe the notes on the safety datasheet.
The conditioning of the coolant for liquid-cooled DEUTZ compact engines is performed by mixing an anti-
freeze with corrosion protection inhibitors based on ethylene glycol into the water.
The cooling system must be monitored regularly.
This also includes checking the coolant system corrosion protection agent concentration in addition to
checking the coolant level.
The cooling system corrosion protection agent concentration can be checked with conventional test
instruments (e.g. refractometer).
Analysisvalues
min max ASTM
phvalue
6,5
8,5
D1293
Chlorine
(Cl)
[mg/l]
-
100
D512
D4327
Sulphate
(SO4)
[mg/l]
-
100
D516
Totalhardness
(CaCO3)
[mmol/l]
[mg/l]
3,56
356
D1126
[°dGH]
20,0
-
[°e]
25,0
[°fH]
35,6
Cooling
system
corrosion
protection
agent
percentage
Water
percentage
Cold
protection
up to
min.35 %
65%
-22 °C
40%
60%
-28 °C
45%
55%
-35 °C
min.50 %
50%
-41 °C
MAINTENANCE
107
Summary of Contents for HORTUS HS CL
Page 1: ...OPERATOR S MANUAL HORTUS HS CL 1 2018 65 Tractor is Zetor Since 1946...
Page 3: ...2...
Page 9: ...NOTES 8...
Page 39: ...HODP038 SAFETY PRECAUTIONS 38...
Page 43: ...NOTES 42...
Page 67: ...NOTES 66...
Page 77: ...NOTES 76...
Page 103: ...Position of the Fuse HODP163 MAINTENANCE 102...
Page 109: ...NOTES 108...
Page 123: ...NOTES 122...
Page 129: ...NOTES 128...
Page 137: ...NOTES 136...
Page 140: ...INDEX 139...