background image

 

1.2

 

Designation of inclinometers 

Inclinometers  are used  for measurement (by  two mutually transverse axes  X and Y) of tilt 

angle of buildings, structures or controlled structural elements.  

The most popular spheres of use of inclinometers are as follows:  

1.

 

Platforms position and alignment control; 

2.

 

Position and movement parameters monitoring of the controlled object; 

3.

 

Alarm notification in the case of critical change of the controlled object’s position; 

4.

 

Security systems; 

5.

 

Navigation. 

The  inclinometers  can  be  used  separately  or  in  the  structure  of  a  distributed  measurement 

system  used  for  control  of  tilt  angle  of  industrial,  residential  and  municipal  facilities.  The 

inclinometers  can  be  easily  installed  on  the  controlled  facility  without  the  need  to  connect  any 

external primary transducers.  

 

1.3

 

Operational environment 

The inclinometers  have industrial  version available and can be used in  adverse operational 

environments. This allows to use them in hostile environments with high mechanical and vibrational 

load. It is allowed to use the inclinometers with labelling 

0ExiaIICT6X 

 in explosion-hazard areas.  

Operational conditions of inclinometers ZET 7x54 are specified in Table 1.1. 

Table 1.1 Operational conditions of ZET 7x54

 

Parameter

 

Industrial version

 

Ambient air temperature, ºС 

-40…80 

Relative air humidity, % 

Not more than 98

1

 

Atmospheric pressure, mmHg 

495-800 

 
 
 
 
 
 
 
 
 
 
 

 

at the ambient air temperature of 35 ºС. 

 

Summary of Contents for ZET 7054

Page 1: ...DIGITAL INCLINOMETER ZET 7054 ZET 7154 USER MANUAL LLC ETMS...

Page 2: ...ntacts labelling 9 2 4 Digital inclinometers mounting 10 2 5 Establishing measuring network connection diagram 11 3 PARAMETERS CONFIGURATION PREPARATION 12 3 1 Connection of digital inclinometers 12 3...

Page 3: ...ng installation start up and pre starting procedure can be conducted by the User or by a representative of the organization performing technical maintenance of the equipment as per provisions of the A...

Page 4: ...tilt angle of industrial residential and municipal facilities The inclinometers can be easily installed on the controlled facility without the need to connect any external primary transducers 1 3 Ope...

Page 5: ...acitance transducer Data refresh rate Hz 1 Data interface RS 485 CAN 2 0 Power supply voltage V 9 24 Consumed power W 0 5 Protections class Industrial version Explosion proof version IP65 IP67 Dimensi...

Page 6: ...Delivery scope of ZET 7x54 Item Quantity 1 Tiltmeter ZET 7 54 1 pc 2 Adjusting plate for ZET 7 54 1 pc 3 Plug for the cable FQ14 4TJ 7 2 pcs 4 CD with ZETLAB SENSOR software 1 pc 5 Product certificate...

Page 7: ...digital inclinometer industrial version General dimensions and mounting dimensions of inclinometer industrial version are specified in Figure 2 2 Figure 2 2 Mounting dimensions of digital inclinomete...

Page 8: ...rnal view of explosion proof product version of the inclinometer is shown in Figure 2 3 Figure 2 3 External view of explosion proof product version of the inclinometer Mounting dimensions of the incli...

Page 9: ...4 V 2 RS 485 line B or DATA CAN 2 0 line H 3 RS 485 line A or DATA CAN 2 0 line L 4 GND Figure 2 5 Contacts labelling for connection to measuring network Connectors FQ14 4ZK S are intended for connect...

Page 10: ...te has four holes with 5 5 mm diameter for mounting on the controlled surface Figure 2 6 Mounting of ZET7x54 with the use of adjustment plate The selected range of tilt angle measurements for measurin...

Page 11: ...connected to the PC by means of interface converter Table 3 1 Figure 2 7 displays the measuring network based on digital transducers ZET 7154 Figure 2 7 Variants of establishing measuring lines with...

Page 12: ...rogram Device manager Configuration of digital transducers is conducted in the program Device manager available in the Service menu of ZETLAB control panel Figure3 1 Figure 3 1 ZETLAB panel The left s...

Page 13: ...Please note that it is necessary to set unique address for every device in the measuring network in the section Address node from 2 up to 63 of the Information tab In order to secure normal operation...

Page 14: ...splays the measured value of the channel at the moment of tab activation Refresh rate Hz Depends on the value selected for the parameter Conversion frequency of the Sensor tab Measurement unit Corresp...

Page 15: ...15 Figure 4 1 shows an example of the tab Axis Figure 4 1 The tab Axis X...

Page 16: ...Exponential moving average order No 256 Number of averaged counts Exponential moving average Yes 0 001 1 Ratio for EMA filter which is calculated by the formula DMAt EMAt 1 DMAt 1 The more is the valu...

Page 17: ...17 Figure 4 2 shows an example of Settings tab Figure 4 2 Settings tab...

Page 18: ...tatus Yes off on If the Offset option is disabled the values by X and Y axes are set to zero The offset value is displayed in the field Displacement by axis of the Settings tab As the Offset function...

Page 19: ...you can visually control the stabilization process with the use of the program multichannel oscilloscope from the scope of ZETLab software Then select the option On and save the settings again The dig...

Page 20: ...nometers 5 1 Checksum control The Metrology tab contains digital ID of the software The field Digital ID should have the value 81964459B471A73B777AD09E1FD45773 Figure 5 1 shows an example of Metrology...

Page 21: ...hronization quality while inclinometers ZET 7054 have only the function of data quality control Figure 5 2 shows an example of the program Synchronization control Figure 5 2 Example of the program Syn...

Page 22: ...5 times The tab Testing Figure 5 3 is used for metrological self check performance Figure 5 3 Testing tab Self check procedure sequence 1 Mount the inclinometer at a horizontal surface 2 Enter the me...

Reviews: