21
5.2
Constant control
The inclinometers have the function of constant control of their operation. To view the results
of the constant control function, start the exe-file of the program “Synchronization control” available
at the directory: C:\ZETLab\SynchronizationControl.exe". The results of the constant control
function operation can be viewed not earlier, than after 5 minutes of program operation.
For inclinometers ZET 7154, it is possible to control the data quality and the synchronization
quality, while inclinometers ZET 7054 have only the function of data quality control.
Figure 5.2
shows an example of the program “Synchronization control”.
Figure 5.2 Example of the program “Synchronization control”
Interpretation of the “Data quality” parameter:
Fine – values in the range from - 15° up to +15°;
Good – values in the range from ± 15° up to ± 80°;
Bad – values in the range from ± 80° up to ± 90°
Not supported – this type of control is not supported.
Interpretation of the “synchronization quality” parameter:
Fine – the tilt meter is synchronized with the interface converter;
Good – synchronization process is active;
Bad – no synchronization;
Not supported – this type of control is not supported.