Physical Details
Wall Mounting
To wall mount the Contour installation dimmer 4
suitable wall fixings are required.
See drawing opposite for dimensions.
Note
Units can be placed side by side. But clearance
above (15mm) and below (120mm) must be left .
With just the top fixing in the wall offer up the
whole unit (Do not remove any panels) to the
top fixings. Locate the top keyway slots over
the screws.
The Contour will now hang on the wall.
Now remove the two lower screws holding the
front panel cover (see picture on page 12 ).
The front cover now lifts off.
Tighten the top two fixings.
Remove the two screws retaining the control
section (see picture on page 12) and lower the
control section on its straps (DO NOT LET IT
DROP).
Fit the two lower wall fixings.
Ventilation
Air enters at the bottom of the unit and exits
through the front panel.
The incoming air supply must be below 40 °C.
WARNING
INSUFFICIENT AIRFLOW WILL
CAUSE OVERHEATING
THE CONTOUR WILL THEN SHUT
DOWN
Wall Mounting
Page 10
7363400/Issue 1/June 00