43
Function
Input signal
high
Input signal
low (0V)
Output
signal
Comment
Control
device
Illustration
Slider out
Out
U0+U1+U6
Ctrl 5
Ctrl 6
Platform is folded
out manually
Platform is folded
in manually
Slider in
1
In
Di1
U0+U1+U7 Normal
Ctrl 5
Ctrl 6
2
C+In+Di1*
U0+U1+U7 Safe
Ctrl 5
Ctrl 6
* Endast krav vid start av rörelse, efter omslag av sensor ignoreras den till dess att omtag sker.
Sensor (Config 1)
Di1
Not in use on this lift model and should not be connected.
Di2
Platform
Angle sensor
Non-actuated Di3 disables Tilt up with the secondary control
device so that the operator must use the two-hand button -
2H along with the primary control device in order to continue
to maintain the tilt up function.
Di3
Liftarm
Angle sensor
For Autotilt, safety function.
Di4
Tiltcylinder
Alarm for open
platform
Pressure sensor for falling pressure connected to +side of lift
cylinder. In the actuated state, returns the connection signal
(+) to Di4 and resulting in output signal (-) at Pa-. Also phase
(+) signal out at Pa+.
Di5
Not in use on this lift model and should not be connected.
Di6
Not in use on this lift model and should not be connected.
Cs
Cabin
Activation
No signal in at Cs results in blocked control device terminals.
Signal to Cs usually comes from the cabin switch. In
individual cases where the cabin switch is not used, the (+)
signal comes in to Cs jumpered from (CS PWR) on nearby
terminal.
2H
Control devices
Two-hand
button
Activated in connection with opening and closing of vehicle
body. Used for Quick opening.
7. Functional schematic drawing