background image

2

806310NZ v1.06 08.19 CW ChillMaster & EconoMaster

Positioning

Allow a clear gap of at least 300 mm on the left side of the 
unit, and 50 mm on the other sides of the unit, to allow air 
flow through the vents (Fig.1).
The average height for the centre line of the water inlet is 
535 mm, and for the waste outlet, 790 mm (Fig.2).
For ChillMaster models: finished height will vary due to 
adjustable feet. Place the unit on a level floor and screw 
the feet in or out as appropriate to make the unit level and 
steady.

Water Supply Requirements

Connect only to cold water 10 - 38°C with a pressure range 
of 150 kPa - 700 kPa. For higher-pressure installations, a 
pressure-limiting valve is required. For ChillMaster models, 
a 500 kPa pressure limiting valve is internal to the unit. 

NOTE: 

No valves are supplied with the SiteMaster and 

EconoMaster. All necessary valves must be supplied 
separately by the installer.

1.  Please read all Warnings and Precautions, and Installation Instructions before installing this 

appliance. Never attempt to install the appliance without reading all of the applicable instructions. 

2.  Plumbing and electrical connections must be made in accordance with local regulations and 

relevant standards. In Australia/NZ: the relevant parts of Plumbing standard AS/NZS 3500 and 
Electrical Wiring Rules AS/NZS 3000.

3.  This appliance must be earthed. 
4.  The power cord and general power outlet must be in a safe and accessible position after installation.
5.  If the power supply cord is damaged it must be replaced by a Zenith Service Provider or a qualified electrician.
6.  Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the 

power supply. 

7.  This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature. 
8.  This unit must not be cleaned by a water jet. This unit must not be positioned in an area that may be cleaned by a 

water jet.

9.  This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 
concerning use of the appliance by a person responsible for their safety. For products sold in Europe, this appliance 
can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning 
use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure 
that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without 
supervision.

10.  This appliance is intended to be used in staff kitchen areas in shops, offices and other working environments; 

farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type 
environments; catering and similar non-retail applications.

11.  The appliance must be placed in an upright position.
12.  Due to the process of continuous improvement, Zenith reserves the right to change details mentioned in this 

manual, without notice. Visit 

zenithwater.co.nz

 to ensure you have the latest copy of this document.

50

MIN

300 MIN

50

MIN

Fig.1 Minimum clearance requirement

FRONT

WATER INLET

CONDENSER

ACCESS PANEL

WARNINGS AND PRECAUTIONS

Installation instructions

Summary of Contents for ChillMaster

Page 1: ...1 806310NZv1 0608 19CWChillMaster EconoMaster Installation instructions usermanual Zenith Freestanding Chilled Water Instantfiltereddrinkingwater AFFIX PRODUCT LABEL HERE...

Page 2: ...under any circumstances without first isolating the appliance from the power supply 7 This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature 8 Thi...

Page 3: ...3 pin plug are fitted Run the cable out of harm s way and plug into a standard 10A power outlet Do not turn the power ON until water flows from the dispense outlet Adjust Bubbler Water Flow When plum...

Page 4: ...ommended in Step 4 as this may damage the slot in the Cartridge Assembly Fixing Nut and make future adjustment impossible Do not force a screwdriver that is wider than the Spring cavity into the cartr...

Page 5: ...he light flashes once per minute When the filter cartridge is due for replacement the light flashes once per second Refer to the Service section for filter timer duration NOTE For safe operation the f...

Page 6: ...mable extended duration timer It is programmable from one to six months in duration A red Light Emitting Diode LED that shows through the front label will flash once per second when the selected filte...

Page 7: ...ains water not connected or turned on Connect or turn on water supply Water pressure regulator failed Contact local Zenith Service Provider Unit frozen up Contact local Zenith Service Provider Interna...

Page 8: ...9 838 8612 Free Call 0800 558 055 Products described in this publication are manufactured under one or more patents and further patent applications are pending As Zenith s policy is one of continuous...