background image

AQUA-CLEER

®

SERIES BXL
and BXL PLUS

WATER TREATMENT
SYSTEMS
MODELS FROM JUNE 2000

©2001 Culligan International Company

Cat. No. 01881997

Rev. D 1/24/01

DCO#1521

Installation

and

Operating

Instructions

Printed in USA

MG10 R/O WATER FILTRATION SYSTEM

Summary of Contents for AQUA-CLEER BXL Series

Page 1: ... and BXL PLUS WATER TREATMENT SYSTEMS MODELS FROM JUNE 2000 2001 Culligan International Company Cat No 01881997 Rev D 1 24 01 DCO 1521 Installation and Operating Instructions Printed in USA MG10 R O WATER FILTRATION SYSTEM ...

Page 2: ...ritten specifically for these individuals and is intended for their use We encourage Culligan users to learn about Culligan products but we believe that product knowledge is best obtained by consulting with your Culligan dealer Untrained individuals who use this manual assume the risk of any resulting property damage or personal injury WARNING IF INCORRECTLY INSTALLED OPERATED OR MAINTAINED THISPR...

Page 3: ...allation 6 Operation 14 Service and Maintenance 16 Parts List 24 Electrical Schematic 31 Wiring Diagram 33 AQUA CLEER SERIES BXL and BXL PLUS WATER TREATMENT SYSTEMS MODELS FROM JUNE 2000 Installation and Operating Instructions MG10 R O WATER FILTRATION SYSTEM ...

Page 4: ...RNING Warning is used to indicate a hazard which could cause injury or death if ignored Example WARNING ELECTRICAL SHOCK HAZARD UNPLUG THE UNIT BEFORE REMOVING THE TIMER MECHANISM OR COVER PLATES The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and careful attention are conditions which c...

Page 5: ...s its dissolved solids content reduced by approximately 96 This high quality product water is sent to service FIG 1 FIG 2 The rest of the feed water contains the total dissolved solids removed from the product water in addition to the total dissolved solids already present in the feed water This concentrate water is sent to drain The amount of total dissolved solids rejected by the system is expre...

Page 6: ... FEED WATER LIMITS Before starting the installation verify that the feed water meets the limits shown in Table 1 and that a water softener is used for pretreatment TABLE 1 FEED WATER LIMITS Property Minimum Maximum Turbidity NTU 0 0 1 0 pH 6 11 Chlorine ppm 0 0 0 1 Total Dissolved Solids ppm 50 2500 Temperature F 33 100 Silt Density Index 0 0 5 0 Iron ppm 0 0 1 0 Short term cleaning is acceptable ...

Page 7: ...using Quantity 1 Cartridge Quantity 1 Cartridge Size in mm 10 254 Cartridge Rating micron 5 Hydraulic RO RO Housing Quantity 2 3 4 RO Element Quantity 2 3 4 RO Element Length in mm 40 40 40 Product Flow gpm L min 0 80 3 03 1 17 4 43 1 53 5 79 Concentrate Flow gpm L min 0 80 3 03 1 17 4 43 1 53 5 79 Operating Weight lb kg 75 34 84 38 93 42 Recovery Design 50 50 50 Minimum 40 40 40 Maximum Feed Pres...