background image

8

HDVI5 Component Video Switch 

HDVI5 Component Video Switch

Using a Different Remote

The HDVI5 features Zektor ’s Exclusive Intelligent-IR™, and with ver y 
few exceptions can be setup to use any remote you can point at it! 
This is useful if you have more than one HDVI5 in the same room.

Pick a new remote

Star t by pick ing a new remote you’d like to use with the 

HDVI5. (Or use the unused buttons on the HDVI5's remote.)
If you plan on using a universal remote, star t by setting 

it up as a remote for a T V or VCR that you don' t own. (For 

instance if you don’t own a Sony T V, setup your universal 

remote to control a Sony T V.)

Step 1: Put the HDVI5 into the Setup Mode

The HDVI5 is placed into the setup mode by pressing and 

holding the Power button for about  seconds.

Step 2: Select the Intelligent-IR™ Learn Mode

Select the Intelligent-IR™ Learn Mode pressing ‘’.
Once the ‘’ button is pressed, the standby LED will flash 

slower and all the other LEDs will turn off. The HDVI5 is 

now waiting for new IR codes to be sent from your remote 

control.

Step 3: Teach the HDVI5 your new remote control codes

On your remote control, press the following buttons, in the 

following order:

 

Power   1   2   3   4   5   0   8   9

The front panel LED's will sequence as each button is 

pressed, and the IR LED will flash for each button -- if not, 

see the following section on 

"More Remote Options".

That ’s it! The HDVI5 will return to the state it was in before 

setup, and will now work with your new remote!

The new control buttons on your remote are...

Power

 

Toggles the HDVI5’s power.

1 - 5

   

Selects inputs  through 5.

0

 

 

Sequences the SEL button (A/V break away).

8

 

 

Toggles Auxiliar y Relay .

9

 

 

Toggles Auxiliar y Relay 2.

Note: 

All remote control codes are saved in non-volatile 
memor y and will not be lost during a power failure.


1                        2                        3                        4                        5                      SEL                     A1          A2

Step 1: Put the HDVI5 into the Setup Mode

Press and hold the Power Button for  secs.

The front panel LEDs will start to blink 

wildly... (You’ll know it when it happens!)

Step 2: Press the ‘1’ button for Intelligent-IR™ learning

1                        2                        3                        4                        5                      SEL                     A1          A2

Step 3: Teach the HDVI5 its new IR codes

1                        2                        3                        4                        5                      SEL                     A1          A2

1       2       3

4       5       6

7       8       9

0

+     +

_     _

POWER

VOL

CH

Press the following sequence of buttons on 

your remote control:

Power    1    2    3    4    5   0   8    9

That’s it!  The HDVI5 now operates with 

your new remote control!

Once the  button is pressed, the 

standby LED will flash slower, and 

all the other LEDs will turn off.

Summary of Contents for HDVI5

Page 1: ...1 2 3 4 5 SEL A1 A2 Z E K T O R Home Theater Switches Digital Video Component Video Multichannel Audio Rev 3 08 08 2006 Digital Video Switch HDVI5...

Page 2: ...thing is missing please get in touch with us as soon as possible so that we can correct the situation 1 2 3 4 What s Inside Contents What s Inside 1 An Overview of the HDVI5 3 Easy Simple Instructions...

Page 3: ...udio compatible IR Input or 12V Trigger Input Accepts modulated or un modulated IR signals or 12V Trigger On Off voltage DVI Output or HDMI Output when using conversion cable Z OUT currently unused re...

Page 4: ...standby mode press and release the Power Toggle button The channel LEDs will all go blank and the standby LED will light up Press the Power Toggle button again to re select the previously selected in...

Page 5: ...upplied Remote Control Use the section of the remote controlled labeled HDVI5 HDMI5 for controlling the HDVI5 The other sections are used to control other Zektor products Each button on the remote fun...

Page 6: ...On your remote control press the following buttons in the following order Power 1 2 3 4 5 0 8 9 The front panel LED s will sequence as each button is pressed and the IR LED will flash for each button...

Page 7: ...HDVI5 will work with most remotes however there are a few exceptions Some technical reasons for not working with some re motes are The remote may be using a carrier frequency outside the range of the...

Page 8: ...eakaway mode Breakaway Video Sets video breakaway mode Aux Relay 1 On Turns on Aux Relay 1 Aux Relay 1 Off Turns off Aux Relay 1 Aux Relay 2 On Turns on Aux Relay 2 Aux Relay 2 Off Turns off Aux Relay...

Page 9: ...ntly selected light mode as follows If 1 s blue LED is lit then front panel lights are always off If 2 s blue LED is lit then front panel is always dim If 3 s blue LED is lit then front panel is alway...

Page 10: ...sted Use the SEL button to toggle between bright and dim settings Step 5 Adjust Front Panel Intensities Use the A1 button to decrease the intensity of the front panel lights Use the A2 button to incre...

Page 11: ...the standby mode It is possible to change the power on behavior of the HDVI5 To change the power on defaults Step 1 Setup the HDVI5 to your preferred power on state Use the front panel buttons to set...

Page 12: ...e front panel buttons Use 4 to enable disable IR control Use 5 to enable disable 12V On Off control Note 1 The IR Jack and 12V On Off control functions are mutu ally exclusive Enabling 12V On Off cont...

Page 13: ...50ms delay Two left justified LEDs 100ms delay Three left justified LEDs 200ms delay Four left justified LEDs 300ms delay Five LEDs 500ms delay Four right justified LEDs 1 sec delay Three right justi...

Page 14: ...lit Long cables are indicated by Blue Red LEDs being lit Use the Power Toggle button to exit the setup mode When a cable s tuning is too short the display will begin to sparkle eventually going blank...

Page 15: ...horizontal pixel size is evenly divisible by four HSync and VSync When set to their default values these settings have no effect on the HSync a VSync signals If a source and monitor will not work with...

Page 16: ...n be setup to turn on for a programmed amount time each time specified channels are selected and then turn off Entering the Relay Setup Mode Place the HDVI5 into the Setup Mode Press and hold the Powe...

Page 17: ...switch to the Momentary Mode the red SEL LED is lit Use the A1 and A2 buttons to adjust the amount of time the relay is active before turning itself off The delay times are indicated by the top row o...

Page 18: ...n input that has been setup to activate the relay When the HDVI5 is switch to an non active channel the relay will turn off after the delay time indi cated by the Blue input selection LEDs Use the SEL...

Page 19: ...like to reset your HDVI5 back to its fac tory default condition this is easily done Step 1 Reset All Parameters to Factory Defaults First press and hold the Power button While continuing to hold the P...

Page 20: ...ol over all features of the HDVI5 All front panel functions supported Full notification of state changes The ability to disable the front panel and still have front panel button presses sent to the se...

Page 21: ...ions can be enabled at a time 12V On Off Control The rear panel jack labeled IR Z IN allows the HDVI5 to be turned on and off using a 12V control voltage To enable disable the 12V On Off control funct...

Page 22: ...andheld Remote Codes Function 807D00FF Power Toggle 807D08F7 1 Button 807D28D7 2 Button 807D18E7 3 Button 807D38C7 4 Button 807D807F 5 Button 807DA05F SEL Button 807D906F A1 Button 807DB04F A2 Button...

Page 23: ...t possible match Allowing cable lengths of 65ft to be used for sparkle free 1080p reception Even longer lengths are achievable at lower resolutions Many other adjustments are also available to help cl...

Page 24: ...p under normal use and service for two years from the origi nal date of purchase ZEKTOR at its option shall repair or replace the defective unit covered by this warranty In order to keep this warranty...

Page 25: ...Z E K T O R Z E K T O R 12675 Danielson Ct Suite 401 Poway CA 92064 858 748 8250 www zektor com...

Reviews: