![ZCS TL Series User Manual Download Page 73](http://html1.mh-extra.com/html/zcs/tl-series/tl-series_user-manual_3222058073.webp)
73 / 74
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Manual of 07/06/2019 Rev. 1.1 “User Manual for 20K-33KTL”
Standard
EMC
EN 61000-6-1/2/3/4
Safety standard
IEC 62116, IEC 61727, IEC 61683, IEC 60068-1/2/14/30, IEC 62109-1/2
Grid connection standard
CE, CGC, AS 4777, AS 3100, VDE-AR-N 4105, EN50438, G83/2, G59/3,
C10/11, CEI 0-21
Communication
Communication interface
Wi-Fi (optional), RS485 (proprietary protocol), microSD card
Additional inputs
I/O inputs for connection to anti-reverse power controller
Data storage
25 years
General information
Ambient temperature
-25°C...+60°C
Topology
Transformerless
Degree of protection
IP65
Relative humidity
0...95% Non-condensing
Maximum operating altitude
2000m
Acoustic emission
<30dB@1m
<45dB@1m
Weight
37 kg
Cooling system
Natural convection
Forced convection
Dimensions
666 x 512 x 254 mm
User interface
LCD display
Warranty