21/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
Step 3:
Loosen the 4 screws (A) using a screwdriver (Fig. 13).
Step 4:
Remove the waterproof cover (B), loosen the cable gland (C), and then remove the cap (G).
Step 5:
Route the TC cable through the cable gland, connect the TC cable to the TC terminal, then insert the TC
terminal into the corresponding port.
Step 6:
A communication cable (between the BMS battery and the HYD-ES inverter) is supplied in the accessory
bag of the HYD-ES inverter. One end is marked “inverter” and the other is marked “BAT.”
Route the communication cable (inverter end) through the cable gland, insert the 4P4C connectors into the
CAN HYD3000/4000/5000/6000-ES port. Insert the 8P8C connector (BAT end) into the CAN port of the
PYLONTECH battery.
Communication cable between the battery and HYD-ES
inverter
CAN communication
HYD-ES inverter
CAN port
CANH---pin1 CANL---pin2
RS485 port
485A----pin3 485B----pin4
PYLONTECH US2000 PLUS / US2000B
CAN port
CANH---pin4 CANL---pin5
RS485 port
485A----pin1& pin8
485A----pin2& pin7
Step 7:
Fasten the waterproof cover using the 4 screws.
NOTE:
If using batteries other than PYLOTECH batteries, please contact the ZCS service centre.
4.4.
Grid connection
Step 1:
Loosen the 4 screws (A) using a screwdriver (Fig. 15).
Step 2:
Remove the waterproof cover (B), loosen the cable gland (C), and then remove the cap (G).
Step 3
: Route a three-pole cable through the GRID cable gland, then connect the three wires to the
corresponding terminal blocks. BROWN - L, BLUE - N, YELLOW / GREEN - PE).
Step 4:
Fasten the waterproof cover using the 4 screws.